Safety Checks And Maintenance Intervals - WAGNER Cobra 40-10/2K Operating Manual

High pressure double diaphragm pump for 2-component products with mixing ratio 1:1
Hide thumbs Also See for Cobra 40-10/2K:
Table of Contents

Advertisement

VERSION 04/2018
OPERATING MANUAL

8.2.3 SAFETY CHECKS AND MAINTENANCE INTERVALS

Every day
Check grounding: see Chapter 6.5.
Check hoses, tubes and couplings: see Chapter 8.2.3.1.
For each decommissioning, the process according to Chapter
followed.
If the pump has to be emptied for maintenance work, proceed according to Chapter
7.5
and Chapter 8.2.4.
Weekly
Check spraying system for damage.
Check that the safety fixtures function properly (see Chapter 5.3).
Yearly or as required
The oil change is to be performed as necessary, at least however, every 12 months in
accordance with Chapter 8.2.8.
In accordance with DGUV regulation 100-500 Chapter 2.29 and 2.36:
– The liquid ejection devices should be checked by an expert (e.g., WAGNER
service technician) for their safe working conditions as required and at least
every 12 months.
– For shut down devices, the examination can be suspended until the next start-
up.
ORDER NUMBER DOC 2349980
Cobra 40-10 / 2K
8.1.2
must be
36

Advertisement

Table of Contents
loading

Table of Contents