IRIG-B-000 IS DEFINED IN IRIG STANDARD 200-04 AS:
1
Format B 100 pps
0 = Pulse width code
0 = No carrier/index count interval
0 = BCD TOY,CF,SBS
IEEE1344 IS DEFINED IN IEEE1344-1995(R2001) ANNEX F AS:
See above

OUTPUT:

Amplitude (DC):
Qty:
Connector:
Phasing:

Time Code Input IRIG-B120 w/ IEEE1344

The selectable Code input has an additional selection for IRIG-B-127. Configuration is via the Keypad /
Display, RS232/422 and the Network port via telnet and HTML.
IRIG-B-120 IS DEFINED IN IRIG STANDARD 200-04 AS:
Format B 100 pps
1 = Sine wave amplitude modulated
2 = 1KHz carrier/1mSec resolution
0 = BCD TOY,CF,SBS
IEEE1344 IS DEFINED IN IEEE1344-1995(R2001) ANNEX F AS:
See section TIME CODE OUTPUT IRIG-B120 200-04 W/ IEEE1344 for definition
XLI SYNC: