F100 Pi - Ping; F100 Pn - Change User Name - Symmetricom XLi User Manual

Time & frequency system
Table of Contents

Advertisement

S
S
S
S
S
S
S
S
S
OK<CR><LF>
In this case, the new password will be used for the next login. However, if the new password is entered
differently the second time, The XLi responds:
ERROR: PASSWORDS DO NOT MATCH. NEW PASSWORD REJECTED.
F100 PI – PING
Use function F100 PI to ping a remote host to see if it is reachable. If no IP Address is provided, F100 PI
uses the XLi's own IP Address, and tests whether the XLi's network port has a good network connection.
To ping a known host, enter:
F100 PI<S><IP Address><CR>
For example:
F100 PI 206.254.000.021<CR>
The unit responds (example):
PING 206.254.000.021: REMOTE HOST FOUND.<CR><LF>
or
PING 206.254.000.021 : REMOTE HOST NOT FOUND.<CR><LF>
To test if the XLi's network port has a good connection, enter the following using in a serial port session:
>f100 PI<CR>
The XLi responds:
PING : REMOTE HOST FOUND.<CR><LF>
or it responds:
PING : REMOTE HOST NOT FOUND.<CR><LF>
F100 PN – Change User Name
Use function F100 PN to change a user name. In a network port session, F100 PN changes the name of
the user you logged in as; operator or guest. In a serial port session, F100 PN changes the name of the
operator user.
See "Command Line Interface" on page 38.
To change the user name, enter:
F100<S>PN<CR>
XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
2
1
5
S
S
S
S
135

Advertisement

Table of Contents
loading

Table of Contents