To set a unique card ID number, compare the SW2 DIP switch settings with those of the other Multicode/
N.8 Frequency Synthesizer cards present. Then set individual switches using the following table as a
guide:
1
Card ID # SW2-1 SW2-2 SW2-3 SW2-4
1
Off
2
On
3
Off
4
On
5
Off
6
On
7
Off
8
On
9
Off
10
On
11
Off
12
On
13
Off
14
On
15
Off
16
On

Adjusting Amplitude and Modulation Ratio

Perform these steps to change the Amplitude and Modulation ratio from the factory defaults. To perform
adjustments:
Remove the top lid of the XLi and retain the screws.
Install the Multicode card in the XLi. Use a top slot so the output level and modulation ratio
potentiometers are accessible by removing the top cover from the XLi chassis. See "Installing or
Removing Option Cards" on page 21.
Using a BNC "T" and coax cables, make a three-way connection between the three following items:
OUTPUT 1 on the 87-6002-XL1 Multicode option card
A load with the desired impedance or the target system
The input connector on an oscilloscope
Adjust potentiometer LEVEL1 (R90) with a tweaker tool for desired voltage amplitude.
Adjust potentiometer RATIO1 (R91) with a tweaker tool for desired voltage ratio.
172
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
S
S
S
S
S
S
S
S
S
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
Off
On
Off
Off
On
Off
On
On
Off
On
On
Off
Off
Off
On
Off
Off
On
On
Off
On
On
Off
On
Off
On
On
Off
On
On
On
On
On
On
On
On
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
S
S
S
S
S
S

Advertisement

Table of Contents
loading

Table of Contents