F77 - PTTI Output Configuration

The Precision Time and Time Interval (PTTI) with BCD/PPS/PPM Output option board status can be
determined via the Serial or Network port using Function F77. Use Serial/Network Function F77 to
obtain information about the part number and the current version of the FPGA installed on the PTTI with
BCD/PPS /PPM option board. To obtain board status information, send the following string to the Serial/
Network port:
F77<SP>B<N><SEP>S<CR><LF>
where:
F
= ASCII character F.
77
= function number.
<SP>
= ASCII space character one or more.
B
= ASCII character to denote Option Bay number follows
<N>
= Option Bay Number, 1 through 10.
S
= ASCII character for "Status Request"
<LT>
= line terminator; for output strings (a carriage return and line feed ) or for input strings (a
carriage return only).
The XLi Serial/Network port will respond with a two-line replay for status request similar to the following
example:
Sample request:
F77 B2 S<CR><LF>
Response:
F77 B2: <CR><LF>
PTTI OUTPUT PART NUMBER
FPGA
To obtain the PTTI Output option board BCD Time Mode information, send the following string to the
Serial/Network port:
F77<SP>B<N><SEP>TM<CR><LF>
where:
F
= ASCII character F.
77
= function number.
XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
87-8045<CR><LF>
230-01510-37v01<CR><LF>
S
S
S
S
S
S
S
S
S
2
1
5
S
S
S
S
109

Advertisement

Table of Contents
loading

Table of Contents