F90 - Code Output Configuration - Symmetricom XLi User Manual

Time & frequency system
Table of Contents

Advertisement

S
S
S
S
S
S
S
1
F90 – Code Output Configuration
Use function F90 to configure the time code output format (IRIG-A, IRIG-B, IRIG-B120 IEEE 1344 or
NASA 36) and modulation type (AM or DC) on the XLi's standard CODE output.
The factory settings for F90 are IRIG-B and AM.
Although the factory configuration outputs UTC time in 24-hour format, the following can be used to
modify the code output of F90 for non-standard applications:
"F2 – 12/24 Hour Format" on page 49
"F69 – Time Mode" on page 89
UTC, and TAI.
Command Line
To display the current settings, enter:
F90<CR>
XLi responds using the following format:
F90<S><CODE OUTPUT><TYPE><CR>
where:
= ASCII character F.
F
= function number.
90
= Space
<S>
<CODE OUTPUT> = IRIG-A, IRIG-B,
= AM, DC
<TYPE>
= carriage return character.
<CR>
= line feed character.
<LF>
For example, enter:
F90<CR>
XLi responds (example):
F90 IRIG-B
AM<CR><LF>
116
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
S
S
S
S
S
S
S
S
S
selects between the following timescales: Local, Standard, GPS,
IRIG-B120 1344,
S
S
S
S
S
S
S
S
S
selects between a 12 or 24-hour time format.
NASA 36
S
S
S
S
S
S
S
S
S
XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
S
S
S
S
S
S

Advertisement

Table of Contents
loading

Table of Contents