Simplex 4100U Application Manual page 39

Smoke management
Hide thumbs Also See for 4100U:
Table of Contents

Advertisement

4100U/4100ES Panels
4100U/4100ES Panel
FigureTag FD4-465-
02
A B C
D E F
G H I
ZONE
SIG
AUX
SYSTEM IS NORMAL
1
2
3
08:23:43 am
MON 11-DEC-00
FB
J K L
M N O
IO
P Q R
IDNet
ALARMS
SYSTEM WARNINGS
AC Power
4
5
6
Fire Alarm
Priority 2 Alarm
Supervisory
Trouble
Alarm Silenced
S T U
V W X
Y Z /
P
A
L
7
8
9
Fire Alarm
Priority 2
Supv
Trouble
Alarm
System
'SP' ( )
, 0 :
Ack
Ack
Ack
Ack
Silence
Reset
NET
ADDR
DEL
0
Enter
C/Exit
Event
More
Time
Info
Previous
Menu
Enable
On
Next
Arm
Disable
Off
Auto
Lamp
Disarm
Test
Emergency Operating Instructions
Alarm or Warning Condition
How to Silence Building Signals
System indicator flashing. Tone On.
Press Alarm Silence.
How to Acknowledge / View Events
How to Reset System
Press ACK located under flashing indicator.
Press System Reset.
Repeat operation until all events are acknowledged.
Press Ack to silence tone device.
Local tone will silence.
Fire Control
(4100U Panel)
The 4100U or 4100ES panel serves as the system controller for the Simplex Smoke Control
System.
It controls the communications between the other system components within the smoke control
system. This panel can be used in a dedicated or a non-dedicated smoke control application.
The 4100U/4100ES connects to other panels in the following ways:
The panel can connect to other Simplex Fire Alarm Control Panels via network communications.
The can also connect to the FSCS using Remote Unit Interface (RUI) serial supervised communications
channel connections.
The Master Controller provides system control, synchronization, and supervision of all modules,
continuously scanning each module for status changes. Features include:
Operator Panel with LCD and operator keys.
Battery Charger for up to 125 Ah Batteries.
– Batteries up to 50 Ah may be mounted in the bottom of the control cabinet
– Batteries larger than 50 Ah mount external to main control cabinet
Compatible with Lead Acid or NiCad Batteries
System Power Supply (SPS), Power Limited:
Supplies 9 A of alarm current and 5 A of standby current.
Two Class A or Class B NACs rated at 3 A each. Supports TrueAlert non-addressable
A/V operation without synch cube.
One 24 V auxiliary power tap, under software control.
Charges 125 Ah batteries per UL 864; 55 Ah batteries per ULC S527.
LCD readout of system voltage and current, battery voltage and current, and NAC current.
Integral 250 point IDNet™ channel.
AC input is 4A @ 120 VAC, 60 Hz; 2A @ 220/230/240 VAC, 60 Hz.
Includes one relay, DPDT, 2A @ 32 VDC
Landing point and control interface for optional two circuit City Card or three circuit
Relay Card. City Card is Reverse Polarity or Local Energy, configurable for alarm,
trouble, and supervisory.
General Operating Specifications
Humidity:
Temperature:
Up to 93% RH, Non-Condensing @ 90° F (32° C) Maximum
32° F to 120° F (0° C to 49° C)
3-3