Various Interface Signals (A2)
1.7 Signals from PLC
1.7
Signals from PLC
Commissioning mode
The ramp-up modes are signaled via bit 0 and bit 1 (VB1800 1000) in the user interface.
Commissioning mode
Normal rampup
Ramp-up with default values
Ramp-up with saved data
40
VB1800 1000.1
0
0
1
Function Manual, 11/2012, 6FC5397-1CP10-5BA0
VB1800 1000.0
0
1
0