Operating Modes, Program Operation (K1)
10.3 Processing a part program
Configuration
The behavior of the ASUB can be influenced via the following standard machine data.
● MD11602 ASUP_START_MASK (ignore stop reasons for ASUB)
● MD11604 ASUP_START_PRIO_LEVEL (priority, as of which MD11602 is effective)
● MD20116 IGNORE_INHIBIT_ASUP (execute interrupt program in spite of read-in disable)
● MD20117 IGNORE_SINGLEBLOCK_ASUP (execute interrupt program completely in
10.3.10

Responses to operator or program actions

Responses
The following table shows the channel and program states that result after certain operator
and program actions.
The left-hand side of the table shows the channel and program states and the mode groups
from which the initial situation can be selected. Various operator/program actions are listed
on the righthand side of the table, the number of the situation after the action has been
carried out is shown in brackets after each action.
188
The machine data specifies which stop reasons are to be ignored for an ASUB start.
Recommended: MD11602 = 'H7'
This machine data specifies the ASUB priority as of which machine data
MD11602 ASUP_START_MASK is to be applied. MD11602 is applied from the level
specified here up to the highest ASUB priority level 1.
Recommended: MD11604 = 2
In spite of set read-in disable, an assigned user ASUB is processed completely for the
interrupt channel with the set bit.
Bit 0 is assigned to interrupt channel 1 (PLCASUP1)
Bit 1 is assigned to interrupt channel 2 (PLCASUP2)
The machine data is effective only if MD11602 ASUP_START_MASK Bit2 = 0
spite of single block)
In spite of selected SBL processing mode, an assigned user ASUB is processed
completely
for the interrupt channel with the set bit.
Bit 0 is assigned to interrupt channel 1 (PLCASUP1)
Bit 1 is assigned to interrupt channel 2 (PLCASUP2)
The machine data is effective only if
MD10702 IGNORE_SINGLE_BLOCK_MASK Bit1 = 0
Turning, Milling, Nibbling
Function Manual, 11/2012, 6FC5397-1CP10-5BA0