Operating Modes, Program Operation (K1)
10.3 Processing a part program
10.3.5

Program control

Selection/activation
The user can control part program processing via the user interface. Under the "Program
control" menu (operating mode AUTOMATIC, operating area "Position") certain functions
can be selected, whereby some functions act on interface signals of the PLC. These signals
are merely selection signals from the user interface. They do not activate the selected
function.
These signal states must be transferred from the PLC user program to another area of the
data block to activate the selected functions. With program control by the PLC the signals
are to be set directly.
Table 10- 4
Function
SKP skip block
DRY dry run feedrate
ROV rapid traverse
override
Preselection:
SBL -single block coarse
SBL -single block fine
Single block
M1 programmed stop
PRT program test
10.3.6

Program status

Program states
The status of the selected program is displayed in the interface in the AUTOMATIC and
MDA operating modes. If the JOG operating mode is selected when the program is stopped,
then the "interrupted" program status is displayed there or on reset also "aborted".
The following program states are available in SINUMERIK 802D:
● IS "Program status aborted" (V3300 0003.4)
● IS "Program status interrupted" (V3300 0003.3)
● IS "Program status stopped" (V3300 0003.2)
● IS "Program status running" (V3300 0003.0)
176
Program control
Selection signal
V1700 0001.0
V1700 0000.6
V1700 0001.3
-
-
User-specific
V1700 0000.5
V1700 0000.7
Activation signal
Checkback signal
V3200 0002.0
V3200 0000.6
V3200 0006.6
-
-
V3200 0000.4
V3200 0000.5
V3300 0000.5
V3200 0001.7
V3300 0001.7
Function Manual, 11/2012, 6FC5397-1CP10-5BA0