Service and Maintenance for Mortise Locks
Caution
Caution
4–20
Task F. To secure the escutcheons and complete the connections:
1. Position the inside and outside escutcheons onto the door.
2. Making sure that the escutcheons do not pinch the wires, secure the
escutcheons to the door—but do not tighten. Use the upper
escutcheon screw at the top trim hole and the lower escutcheon
screw at the bottom trim hole.
When routing the solenoid and sensor wire harness, the sensor wires,
and the solenoid wires, make sure the wires are not rubbed across
any sharp edges or over any surface that could damage their sleeving
or wire insulation.
3. Make the solenoid connection and three sensor connections, and
place the wires into the inside trim.
Wire connection
Solenoid
RQE
Shorting connection
Door status sensor
When making the sensor connections and solenoid connection, make
sure:
there are no loose wire connections where the wires are inserted
into the sensor and solenoid connectors
the sensor and solenoid wire harness connector is fully seated in
its mating connector on the control electronics circuit board.
Inside of door
Figure 4.21 Securing the escutcheon and completing the connections
Color
No. of wires
Yellow
Brn/Org
Purple
White
Inside escutcheon
Upper escutcheon screw
Make these
connections.
Lower escutcheon screw
No. of pins
2
3
2
3
2
2
2
2
W Series Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

35hw83kw93kw34hw85kw95kw ... Show all

Table of Contents