Installation Instructions for 34HW–35HW IDH Max Mortise Locks
Access holes
Field wires
Splice
connectors
Wire transfer
hinge
Door frame
Figure 18 Installing the wire transfer hinge
16
Completing the installation at the door
18
1 Trim the four wires of the field wire harness, which you
pulled through the hinge edge of the door in Task 8.
Leave sufficient length to connect to the wire transfer
hinge.
2 Splice the power and communication field wiring to
Field wire
the four pairs of leads on the frame side of the hinge,
harness leads
following the hinge manufacturer's instructions.
3 Splice the four field wire harness wires (listed in the
table below) to the four pairs of leads on the door side
of the hinge, matching each pair of leads to its
corresponding field wire.
Wire
Ground
12 VDC
Door
Com+
Com–
4 Insert the wires and splice connectors into the holes or
pockets in the door and frame, being careful not to
pinch the wires. Install the wire transfer hinge.
BEST ACCESS SYSTEMS
Indianapolis, Indiana
Install wire transfer hinge
Color
Black
Red
Orange
Green

Advertisement