Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
Inside of door
Figure 16 Securing the through-bolt trim and
completing connections
14
Inside trim
Combination
mounting screw
Make these
connections.
Standard
mounting screw
BEST ACCESS SYSTEMS
Indianapolis, Indiana
Installing the lock & through-bolt trim
16
Secure through-bolt trim and complete
connections
1 Position the inside and outside trim onto the door.
2 Making sure that the trim does not pinch the
wires, secure the trim to the door—but do not
tighten. Use the combination mounting screw at the
top trim hole and the standard mounting screw at the
bottom trim hole.
Caution: When routing the solenoid and sensor
wire harness, the sensor wires, and the solenoid
wires, make sure the wires are not routed across
any sharp edges or over any surface that could
damage their sleeving or wire insulation.
3 Make the three (3) sensor connections and solenoid
connection, and place the wires into the inside trim.
Wire connection
Solenoid
RQE
Shorting connection
Door status sensor
Caution: When making the sensor connections
and solenoid connection, make sure:
there are no loose wire connections where the
wires are inserted into the connectors
the connectors are firmly mated.
No. of
No. of
Color
wires
pins
Yellow
2
3
Brn/Org
2
3
Purple
2
2
White
2
2