BEST ACCESS SYSTEMS W Series Service Manual page 146

Table of Contents

Advertisement

Additional Service and Maintenance for IDH Max Locks
Caution
Caution
6–6
Do not use a power screwdriver to remove or reinstall the circuit
board screw.
9. Disconnect the field wire harness from the control electronics
circuit board.
Connect field wire
harness here.
Figure 6.3
Connecting the wire harnesses to the control electronics circuit board
Reinstalling the field wire harness
1. Connect the field wire harness to the control electronics circuit
board. See
Figure
2. Reinstall the field wire harness strain relief and install the circuit
board screw. Try to start the circuit board screw without laying the
strain relief flush against the control electronics circuit board. Then
tighten the screw.
Remember to reinstall the field wire harness strain relief. The lock
may be damaged or not operate properly without the strain relief.
3. Pull the field wire harness through the door and connect the field
wire harness to the wire transfer hinge. For mortise instructions,
see Task A. To pull the field wire harness through the door: on
page
4–13. For cylindrical instructions, see Task A. To pull the field
wire harness through the door: on
4. For mortise locks, perform the following steps:
Reinstall the mortise case. See Task B. To reinstall the mortise
case: on
page
4–14.
Reinstall the mounting plates. See Task C. To reinstall the
mounting plates: on
Reinstall the cylinder and mortise case faceplate. See Task D. To
reinstall the cylinder and mortise case faceplate: on
6.3.
page
page
4–15.
Connect reader
wire harness here.
Install strain
relief here.
5–8.
page
4–16.
W Series Service Manual