Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
Site survey
Use the following survey to record information about the
installation site. You need this information to determine
field wiring needs, select a power supply, and determine
how to prepare the door for the lock.
Lock information
Lock function:
DDEL–Electrically locked
DDEU–Electrically unlocked
Power source for lock:
Separate power supply
Power provided through panel interface module
Power source for panel interface module:
Separate power supply
Power provided through access control panel
Distance of lock site from lock power source:
Distance of lock site from panel interface module site:
feet
Door information
Door handing and bevel:
Left hand (LH)
Left hand, reverse bevel (LHRB)
Right hand (RH)
Right hand, reverse bevel (RHRB)
Door thickness:
inches (1 3/4" – 2 1/4" ; 1 3/8" with
spacer)
Environment information
Ambient temperature:
Is within specifications. See the tables below.
This product meets the following Locked Door Outdoor
test requirements for ANSI/BHMA 156.25:
Side of door
Range
Inside
+66°F to +74°F (+19°C to +23°C)
Outside
–31°F to +151°F (–35°C to +66°C)
This product meets the following Full Indoor test
requirements for ANSI/BHMA 156.25:
Side of door
Range
Inside and outside
+32°F to +120°F (0°C to +49°C)
2
Components checklist
Use the following checklist to make sure that you have the
items necessary to install the components provided with
your 83KW/93KW–85KW/95KW IDH Max Cylindrical Lock.
Components provided in the box:
Chassis with outside knob/lever and outside rose liner
assembly
Inside escutcheon assembly with field wire harness
Inside escutcheon access door
Inside rose liner with RQE feature
Outside escutcheon assembly
Inside knob/lever
Throw member package
Latch
feet
Door status switch & magnet assembly
Plastic bushing package
Hub washers
Trim hole insert package
Escutcheon screw package
Panel interface module
Strike package
Bar code ID sticker (for your records)
Other items you'll need:
Power supply for one IDH Max Cylindrical Lock (if
you're providing a separate power supply): regulated;
12 volts DC at .85 amps
Note: If you intend to power more than one lock with the
same power supply, calculate the amperage for the
power supply by multiplying .85 by the number of
IDH Max Cylindrical Locks (1.1 by the number of IDH Max
Mortise Locks).
Power supply for the panel interface module (if you're
providing a separate power supply): 12 volts DC at
.1 amp
Wire transfer hinge: 8 conductors min.; 28 AWG min.
continued