INSPECTION
Blower motor does not operate
1. Check "BLOWER fuse/Relay
(1) Check "BLOWER" fuse.
Fuse
BLOWER
(2) If fuse is open check for a short-circuit in wiring harness before replacing "BLOWER" fuse.
(3) If fuse is OK proceed to inspection.
Blower relay
1. Disconnect blower relay.
2. Check continuity between terminals of relay.
3. If not as specified, replace relay.
4. If correct go to next step.
5. Apply 12V to terminal 85and ground terminal 86.
6. Check for continuity between terminals 87 and 30.
7. If not as specified, replace relay.
8. If correct, go to step2.
Terminals
85-86
87-30
Terminals
87-30
Amperage
30A
Location
Engine compartment fuse box
Continuity
Yes
No
Continuity
Yes

Advertisement