Before You Begin
Table 1-1
Obtaining version information (continued)
Component
Core processor software
ProLink II
(1)
GSD version
EDD version
(1) There are two GSD options available: Manufacturer-specific and Profile-specific. See Section 2.5 for more information.
1.6

Communication tools

Most of the procedures described in this manual require the use of a communication tool. Table 1-2
lists the communication tools that can be used, with their functionality and requirements.
Note: You can use ProLink II, the EDD, or PROFIBUS bus parameters for transmitter setup and
maintenance. It is not necessary to have more than one of these methods available.
Table 1-2
Communication tools for Model 2700 transmitter with PROFIBUS-PA
Tool
Transmitter display
ProLink II
(1)
Host
EDD
Bus parameters
(1) There are two GSD options available: Manufacturer-specific and Profile-specific. See Section 2.5 for more information.
The PDM and GSD files can be downloaded from the following address:
http://www.emersonprocess.com/micromotion/softwaredownloads
Also available at this address is a document titled Commissioning MVD Profibus PA Documentation
Supplement. This supplement will assist you with connecting to the transmitter with Siemens
®
Simatic
Process Device Manager (PDM). If you are using Simatic PDM, download the PDM file set
and follow the EDD instructions in this manual.
Basic information on using the display is provided in Appendix B.
Basic information on ProLink II is provided in Appendix C. For more information, refer to the
ProLink II manual, which is available on the Micro Motion web site (www.micromotion.com).
Although some functions of the Model 2700 transmitter with PROFIBUS-PA may be available
through earlier versions of ProLink II, version 2.92 with the Build 9827 patch or a later version is
required for full configuration, maintenance, and operation.
Configuration and Use Manual
Tool
With ProLink II
With EDD
With display
With ProLink II
Text editor
Text editor
Functionality
View/operation
Setup/maintenance
Partial
Partial
Full
Full
Partial
None
Full
Full
Full
Full
Method
Not available
Not available
OFF-LINE MAINT > VER
Help > About ProLink II
Open file V3x_057A.gsd or PA139742.GSD and
check parameter GSD_Revision
Open file MMIcorflow.DDL and check parameter
DD_REVISION
Requirements
Transmitter with display
ProLink II v2.92 or later
GSD file V3x_057A.gsd or
PA139742.GSD
PDM file set
None
®