Subaru Legacy 2005 Service Manual page 1048

Hide thumbs Also See for Legacy 2005:
Table of Contents

Advertisement

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES)
5. Purge Control Solenoid Valve
A: REMOVAL
1) Remove the collector cover.
2) Disconnect the ground cable from battery.
3) Remove the solenoid valve bracket assembly
from intake manifold.
4) Disconnect the connector from purge control so-
lenoid valve.
5) Disconnect the evaporation hose from the intake
manifold and fuel pipe assembly.
6) Remove the purge control solenoid valve from
solenoid valve bracket assembly.
Purge Control Solenoid Valve
IN-00203
EC-00219
EC-00220
EC(H4DOTC)-6
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
19 N
m (1.94 kgf-m, 13.7 ft-lb)
NOTE:
Connect the evaporation hose as shown in the fig-
ure.
(A)
(A) To intake manifold
(B) To fuel pipe ASSY
Tightening torque:
19 N
m (1.94 kgf-m, 13.7 ft-lb)
C: INSPECTION
Make sure the hoses are not cracked or loose.
EC-00220
(B)
EC-00273
EC-00219