Removing The Blower Motor Assembly - KitchenAid JOB AID 4317282 Technical Education

Professional dual fuel range with self-clean thermal convection oven
Table of Contents

Advertisement

REMOVING THE BLOWER MOTOR ASSEMBLY

WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range.
Replace all panels before operating range.
Failure to do so can result in death or electri-
cal shock.
FIRE HAZARD
Shut off gas supply line valve before servic-
ing the range.
Check all gas line connections and replace
all panels before operating the range.
Failure to do so could result in explosion, fire,
or other injury.
CAUTION: When you work on the dual fuel
range, be careful when handling the sheet
metal parts. Sharp edges may be present, and
you can cut yourself if you are not careful.
1.
Turn off the gas and electrical power going
to the range.
2.
Pull the range away from the wall so that
you can access the rear panel.
3.
Remove the braces and rear panel from
the range (see page 2-17).
4
Remove the four screws from the blower
motor assembly cover and remove the
cover from the range.
5.
Remove the four mounting screws and the
air vent screw from the blower motor as-
sembly and remove the assembly from
the range.
Screw 1 of 4
Blower Motor
Assembly
2-20
Screw 1 of 4
Blower Motor
Assembly Cover
Air Vent Screw

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdrp407hss

Table of Contents