WARNING
Electrical Shock Hazard
Disconnect the electrical supply from the
unit before servicing.
Failure to do so could result in death or
electrical shock.
TEST PROCEDURE
Refer to page 2-14 for the procedure for ser-
vicing the broil element.
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R x 1 scale.
3.
Disconnect the wires from the broil ele-
ment terminals.
4.
Touch the ohmmeter test leads to the broil
element terminals. The ohmmeter should
indicate 45 to 55 Ω.
ELECTRONIC RANGE
CONTROL
P5-1
P5-2
P5-5
DOUBLE LINE
BREAK RELAY
BROIL ELEMENT
CONV-1600W
Y
BAKE-2000W
R
BROIL-3000W
BU
R
R
Disconnect This
Red Wire
Resistance Test (At The Electronic
Range Control)
NOTE: To test the broil element at the elec-
tronic range control, perform the following steps
(see page 2-4 for removing the top access
panel).
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R x 1 scale.
3.
Disconnect the P5-5 (blue) wire and the
red wire that is on the common side of the
double line break relay (refer to the sche-
matic) on the electronic range control.
4.
Touch the ohmmeter test leads to the blue
and red wires. The ohmmeter should indi-
cate 45 to 55 Ω.
OVEN SHUTDOWN
THERMAL FUSE
NON-RESETTABLE
3-9