Parameters For Configuring Fb 169; Parameter Assignments - Siemens Simatic S5 IP 240 Manual

Counter/positioning/position decoder module
Hide thumbs Also See for Simatic S5 IP 240:
Table of Contents

Advertisement

IP 240
Name
Para-
Data
meter type
type
BGAD
D
KF
KANR
D
KF
DBNR
D
KF
AFL
D
KF
IMP
D
KF
DIG1
D
KM
DIG2
D
KM
PRA1
D
KM
PRA2
D
KM
PAFE
A
BY
BER
D
KF
*
ABIT
D
KY
**
*
not required for FB 169 for the S5-115U
**
not required for FB 169 for the S5-115U and S5-135U

Parameter assignments

BGAD: KF
128 to 240
0 to 240
KANR : KF
1
2
DBNR : KF
3 to 255
AFL
: KF
1
2
4
IMP
: KF
0
10
16
EWA 4NEB 811 6120-02a
Table 7-5. Parameters for Configuring FB 169
Description
Module starting address
Channel number
Data block number
Resolution of encoder pulses
Zero mark monitoring
Assignment of digital output D1 to reference tracks 1 to 8
Assignment of digital output D2 to reference tracks 1 to 8
Assignment of a process interrupt to reference tracks 1 to 8
Assignment of a process interrupt to bits in the status area
Error identifier byte
Address range (I/O area and extended I/O area)
Evaluation of the signal transition for interrupt processing with
PY 0 Interrupt bit reserved in I/O byte 0.
Starting address of module in P area, divisible by 16
Starting address of module in Q area, divisible by 16
Channel 1
Channel 2
Number of the data block created
Single resolution
Twofold resolution, corresponds to doubling of encoder pulses
Fourfold resolution, corresponds to quadrupling of encoder pulses
No zero mark monitoring
Number of pulses between two zero marks divisible by 5 (without
remainder)
Number of pulses between two zero marks divisible by 4 (without
remainder)
Position Decoding
7-19