Switching The Ip Outputs; Ip Outputs Control The Traverse Speed; Setting The Ip Outputs Separately - Siemens Simatic S5 IP 240 Manual

Counter/positioning/position decoder module
Hide thumbs Also See for Simatic S5 IP 240:
Table of Contents

Advertisement

IP 240
Axis types
-9,999,999
Maximum
actual value
For a rotary axis, the IP 240 always chooses the direction so that the target position is reached
along the shortest possible path. You can influence the range of the actual position by forwar-
ding a zero offset to the IP.

Switching the IP outputs

The IP 240 is equipped with two digital outputs per channel. When a position has been selected,
the IP 240 sets the enabled outputs autonomously and resets or disables them when the switching
points are reached.
In order to better adapt the IP 240 to your application, you can specify how the outputs are to be
switched when you configure the IP.
a) The IP outputs control the traverse speed
The speed is switched from rapid traverse to creep speed when the BEE1 range is entered. The
drive is switched off when the BEE2 range is entered.
You can also specify whether the outputs are to be set separately ( Fig. 10-6 a) or collectively
( Fig. 10-6 b).
Rapid traverse
v
Selection of the
target position
Actual
value
Out-
put
D1
D2
a) Setting the IP outputs separately
EWA 4NEB 811 6120-02a
Table 10-3. Axis Types and Actual Value Ranges
Linear axis
Table
-1
+1
+9,999,999
0
-
9,999,999 to +9,999,999
Creep
speed
BEE1
BEE2
Target
position
Fig. 10-6. IP Outputs Control the Traverse Speed
Rotary axis
9,999,998
0 to 9,999,998
Rapid traverse
v
Selection of the
target position
b) Setting the IP outputs collectively
Positioning
0 1
Creep
speed
BEE1
BEE2
Target
position
10-7