IP 240 Counter, Position Decoder and Positioning Module
Start-up Program and Error Responses
Start-up Program
The start-up program is in OB 100. When OB 100 has been processed, you
can check the following entries with "Monitor/Modify variable":
The actual value
If all inputs show the signal state '0', no output may be activated.
Responses to
If an error or fault occurs during execution of the start-up program, the cyclic
Errors
block calls are no longer processed; the error memory bit is set.
After every block call in the cyclic program, an error is flagged when an
error occurs (BR = '0'), which in turn causes a group error message to be
output at Q 1.7 (M 191.7).
In the case of a group error message, the associated error bit indicates which
block call has caused the error. A precise description of the error can be
found in the corresponding PAFE byte and in the error words of the data
block (see the IP 240 Manual, Sections 10.23.1 "Configuring Function
Block" and 10.23.2 "Control Function Block").
C-30
DB 170.DBB 2 to DBB 7:
DB 170.DBB 8 to DBB 13:
DB 170.DBB 14 and DBB 15:
DB 170.DBB 46:
DB 170.DBW 48:
DB 170.DBW 52:
DB 170.DBD 60:
is the value of the zero displacement.
The returned position number
DB 168.DBW 56
is the value W#16#00FF (no position selected).
Product code of the module
Firmware version
Hardware version
B#16#041 ("Positioning" mode)
Data block number
Basic address of the module
Actual value (BCD-coded or
binary-coded, depending on how
the BCD parameter is assigned)
Number of position to be approached
EWA 4NEB 811 6120-02b