Siemens Simatic S5 IP 240 Manual page 114

Counter/positioning/position decoder module
Hide thumbs Also See for Simatic S5 IP 240:
Table of Contents

Advertisement

Position Decoding
FB 25
NETWORK 1
0000
FB25 : OPERATION / TRAVERSE PROGRAM OF THE INDUCTION FURNACE
FB25 ENTERS THE INITIAL OR RETURN SPEED OF THE FURNACE
INTO FW14 AND PARAMETERIZES A CONTROL TRACK (TRACK 8), IF
NECESSARY, TO MOVE THE FURNACE BACK TO ITS ORIGINAL POSITION.
NAME :OPERATE
0005
:A
F
12.4
0006
:JC
=R-PR
0007
:A
F
12.2
0008
:JC
=FOR1
0009
:C
DB
10
000A
:L
DW
3
000B
:T
FW
14
000C
:AN
F
12.2
000D
:S
F
12.2
000E
:S
Q
12.4
000F
:
0010 FOR1 :A
F
12.6
0011
:R
Q
12.4
0012
:JC
=FOR2
0013
:BEU
0014 FOR2 :
0015
:C
DB
12
0016
:L
KB 0
0017
:T
DW
64
0018
:T
DW
65
0019
:L
KH 0109
001B
:T
DW
62
001C
:L
KH 9999
001E
:T
DW
63
001F
:L
KH 0080
0021
:T
DR
29
0022
:JU
FB 170
0023 NAME :STEU.WEG
0024 DBNR :
KF +12
0025 FKT
:
KF +4
0026 PAFE :
FY
2
0027
:L
FY
2
0028
:L
KB 0
0029
:><F
002A
:=
F
11.6
002B
:
002C
:C
DB
10
002D
:L
DW
11
002E
:T
FW
14
002F
:AN
F
12.4
0030
:S
F
12.4
0031 R-PR :
0032
:A
F
12.7
0033
:JC
=KSET
0034
:BEU
0035 KSET :
0036
:AN
F
0.0
0037
:R
Q
12.1
0038
:S
Q
12.2
0039
:R
F
12.2
003A
:R
F
12.4
003B
:R
F
12.6
003C
:R
F
12.7
003D
7-50
OPERATION / TRAVERSE PROGRAM
-BACK ACTIV
-FORW ACTIV
-ANALOG VAL
-FORW ACTIV
-FORW ACTIV
-HEATING
-FIN POINT
-HEATING
-AUX BYTE1
-AUX BYTE1
-PAFE TRAC8
-ANALOG VAL
-BACK ACTIV
-BACK ACTIV
-INT POINT
-ZERO SIGNAL
-RUNNING
-ENABLED
-FORW ACTIV
-BACK ACTIV
-FIN POINT
-INT POINT
LEN=67
OUTPUT SPEED ZONE 1
SWITCH ON HEATING
FEEDBACK FROM INTERRUPT SERVICE ROUTINE
SWITCH OFF HEATING
SET FINAL VALUE TRACK 8
TO ZERO
SET INITIAL VALUE
TO -99999
BITS FOR TRACKS USED
(ONLY TRACK 8 RELEVANT)
WRITE TRACK LIMITS
PAFE FOR WRITING TRACK LIMITS
SET SCRATCH FLAGS
FEEDBACK FROM INTERRUPT SERVICE ROUTINE
IP 240
EWA 4NEB 811 6120-02a

Advertisement

Table of Contents
loading

Table of Contents