Siemens Simatic S5 IP 240 Manual page 122

Counter/positioning/position decoder module
Hide thumbs Also See for Simatic S5 IP 240:
Table of Contents

Advertisement

Position Decoding
FB 39
NETWORK 1
0000
WRITE THE STATES OF FLAG WORDS 200 - 254 SAVED BACK TO
THE FLAG WORDS. THE DATA BLOCK SPECIFIED MUST HAVE A LENGTH OF
AT LEAST 30 DATA WORDS (DW0 - 29).
NAME :LOAD.FLG
ID
:DBNR
I/Q/D/B/T/C: B
0008
:B
=DBNR
0009
:***
NETWORK 2
000A
000A
:L
KF +0
000C
:T
DW
28
000D
:L
KF +200
000F
:T
DW
29
0010 M001 :DO
DW
28
0011
:L
DW
0
0012
:DO
DW
29
0013
:T
FW
0
0014
:L
DW
28
0015
:ADD BF+1
0016
:T
DW
28
0017
:L
DW
29
0018
:ADD BF+2
0019
:T
DW
29
001A
:L
KF +254
001C
:L
DW
29
001D
:>=F
001E
:JC
=M001
001F
:BE
7-58
LOAD FLAGS
PRESET THE POINTERS
DATA WORD POINTER
FLAG WORD POINTER
INCREMENT POINTERS
FLAG WORDS UP TO
AND INCLUDING FW254
LOADED ?
LEN=37
EWA 4NEB 811 6120-02a
IP 240

Advertisement

Table of Contents
loading

Table of Contents