9.11 ADF unit
9.11.1 ADF unit
(1) Remove the ADF FFC holder from the Panel flat cable, the First side CIS flat cable, and the
Second side CIS flat cable.
(2) Remove the Taptite bind B M4x12 (black) screw from the Hinge ASSY L.
Hinge ASSY L
Taptite bind B M4x12 (black)
Assembling Note:
• Attach the Panel flat cable, the First side CIS flat cable, and the Second side CIS flat
cable to the ADF FFC holder as shown in the figure below.
ADF FFC holder
Second side CIS flat cable
(For models with ADF)
First side CIS flat cable
ADF FFC holder
Second side CIS flat cable
Panel flat cable
Fig. 3-28
Panel flat cable
Fig. 3-29