9.10
ADF Unit (For models with ADF)
9.10.1 ADF Unit
(1) Remove the taptite cup S M3x6 SR screw, and remove the ADF FG harness and the FB
FG harness.
(2) Disconnect the two connectors from the main PCB ASSY.
FB FG harness
Taptite cup S M3x6
ADF FG harness
Main PCB ASSY
Connector
(ADF motor
harness ASSY)
Fig. 3-26
3-44
Connector
(ADF sensor
harness unit)
CN6
CN24
Main PCB ASSY
Confidential