9.20 New toner sensor PCB ASSY
(1) Disconnect the New toner sensor flat cable from the High-voltage power supply PCB
ASSY, and release the Hook to remove the New toner sensor PCB ASSY. Disconnect the
Registration front/rear sensor harness from the New toner sensor PCB ASSY.
High-voltage power
supply PCB ASSY
Harness routing: Refer to
New toner sensor PCB ASSY
New toner sensor flat cable
<Front side>
Hook
Fig. 3-70
"8. Rear side of the
Registration front/rear sensor harness
machine".
3-75
Confidential