Brother DCP-7090 Service Manual page 237

Laser mfc
Hide thumbs Also See for DCP-7090:
Table of Contents

Advertisement

 MP models
(1) Disconnect the MP relay flat cable from the Main PCB ASSY.
(2) Release the MP sensor harness and the MP paper empty sensor harness from the
securing fixtures.
(3) Remove the Taptite bind B M4x12 screw. Remove the MP relay PCB ASSY, and
disconnect each harness from the MP relay PCB ASSY.
MP relay PCB ASSY
MP relay flat cable
Main PCB ASSY
Harness routing: Refer to
Assembling Note:
• Secure each harness in the Hooks in order of the Hook A to E, and then secure
them in the Hooks from the Hook F to G. Be sure to give them enough slack in the
H part for adjustment.
Taptite bind B M4x12
MP paper empty sensor harness
MP sensor harness
MP relay flat
cable
Hook A
Hook F
Fig. 3-75
"9. Top side of the
machine",
3-80
Hook B
Hook C
Hook D
H part
Hook G
"11. Frame L unit (MP
models)".
Hook E
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents