Setup Mode Organization
STEP
STEP
FUNCTION
2-WIRE CL SENSOR SETUP
STEP
STEP
STEP
STEP
FUNCTION
3-WIRE CL SENSOR SETUP
STEP
STEP
STEP
STEP
FUNCTION
EXTERNAL INPUT SETUP
STEP
STEP
STEP
STEP
FUNCTION
OUTPUT RELAY SETUP
STEP
STEP
STEP
STEP
FUNCTION
PLLD LINE DISABLE SETUP
STEP
FUNCTION
WPLLD LINE DISABLE SETUP
STEP
Sensor Location
Category (Annular Space/Dispenser Pan/Monitor Well/STP Sump/Piping Sump/Other)
Sensor Config. - Module 1 (up to 8)
Sensor Location
Sensor Types (Discrim. Interstitial/Ultra 2)
Category (Annular Space/Dispenser Pan/Monitor Well/STP Sump/Piping Sump/Other)
Sensor Config. - Module 1 (up to 8)
Sensor Location
Sensor Mode (Standard/High Vapor)
Category (Annular Space/Dispenser Pan/Monitor Well/STP Sump/Piping Sump/Other)
Input Config. - Module 1 (up to 8)
Input Name
External Input Type (Standard [NO/NC]/Generator [Select Orientation (NO/NC)/Generator
Tank [All Tanks/By Tank]/Pump Sense [Select Orientation (NO/NC)/Select Tank (Tank #/
None)/Dispense Mode)
Standard ACK (NO/NC)
Relay Config. - Module 1 (up to 8)
Enter Relay Designation
Select Relay Type (Standard [NO/NC]/Pump Control Output [Select Tank (None/Tank #)]/
Momentary [NO/NC]/Pump Comm Control [Select Tank (None/Tank #)])
Relay Assignments - for each relay except Pump Comm Control types (In-Tank Alarms [None/
All /Single]/ Liquid Sensor Alarms [None/All /Single]/ Vapor Sensor Alarms [None/All /Single]]/
External Inputs [None/All /Single]]/ Line Leak Alarms - VLLD [None/All /Single]/ Groundwater
Alarms [None/All /Single]/ 2-Wire CL (Type A) Alarms [None/All /Single]/ 3-Wire CL (Type B)
Alarms [None/All /Single]/ Power Side DIM Alarms [None/All /Single]/ Reconciliation Alarms
[None/All /Single]/ PLLD Alarms [None/All /Single]/ WPLLD Alarms [None/All /Single]/ Comm
Side DIM Alarms [None/All /Single]/ Pump Relay Monitor Alarms [None/All /Single]
Relay Assignments - for each relay except Pump Comm Control types (In-Tank Alarms [None/
All /Single]/ Liquid Sensor Alarms [None/All /Single]/ Vapor Sensor Alarms [None/All /Single]]/
External Inputs [None/All /Single]]/ Line Leak Alarms - VLLD [None/All /Single]/ Groundwater
Alarms [None/All /Single]/ 2-Wire CL (Type A) Alarms [None/All /Single]/ 3-Wire CL (Type B)
Alarms [None/All /Single]/ Power Side DIM Alarms [None/All /Single]/ Reconciliation Alarms
[None/All /Single]/ PLLD Alarms [None/All /Single]/ WPLLD Alarms [None/All /Single]/ Comm
Side DIM Alarms [None/All /Single]/ Pump Relay Monitor Alarms [None/All /Single]
Relay Assignments - for each relay except Pump Comm Control types (In-Tank Alarms [None/
All /Single]/ Liquid Sensor Alarms [None/All /Single]/ Vapor Sensor Alarms [None/All /Single]]/
External Inputs [None/All /Single]]/ Line Leak Alarms - VLLD [None/All /Single]/ Groundwater
Alarms [None/All /Single]/ 2-Wire CL (Type A) Alarms [None/All /Single]/ 3-Wire CL (Type B)
Alarms [None/All /Single]/ Power Side DIM Alarms [None/All /Single]/ Reconciliation Alarms
[None/All /Single]/ PLLD Alarms [None/All /Single]/ WPLLD Alarms [None/All /Single]/ Comm
Side DIM Alarms [None/All /Single]/ Pump Relay Monitor Alarms [None/All /Single]
3-7
Setup Mode Programming Table