Communication Objects Send Pdo - Siemens Sinamics S120 Commissioning Manual

Canopen interface
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Add infeed
2.5 CANopen object directory
2.5.2.2

Communication objects send PDO

The following table lists the object directory with the index of the individual drive-dependent
communication objects for the transmit PDO of the first drive object:
Table 2- 4
Drive-dependent communication objects for transmit PDO
OD
Subindex
Object name
index
(hex)
(hex)
1800
Transmit PDO 1
communication
parameter
0
Largest subindex
supported
1
COB ID used by
PDO
2
Transmission type
3
Inhibit time
4
Compatibility entry
5
Event timer
1801
Transmit PDO 2
communication
parameter
0
Largest subindex
supported
1
COB ID used by
PDO
2
Transmission type
3
Inhibit time
4
Compatibility entry
5
Event timer
1802
Transmit PDO 3
communication
parameter
0
Largest subindex
supported
1
COB ID used by
PDO
2
Transmission type
3
Inhibit time
4
Compatibility entry
5
Event timer
1803
Transmit PDO 4
communication
parameter
0
Largest subindex
supported
44
SINAMICS
PDO map-
parameters
ping
No
p8720.0
No
p8720.1
No
p8720.2
No
p8720.3
No
p8720.4
No
No
p8721.0
No
p8721.1
No
p8721.2
No
p8721.3
No
p8721.4
No
No
p8722.0
No
p8722.1
No
p8722.2
No
p8722.3
No
p8722.4
No
No
Data type
Predefined con-
nection set
Unsigned8
5
Unsigned32
180 hex + node ID
Unsigned8
FE hex
Unsigned16
0
Unsigned8
3
Unsigned16
0
Unsigned8
5
Unsigned32
280 hex + node ID
Unsigned8
FE hex
Unsigned16
0
Unsigned8
0
Unsigned16
0
Unsigned8
5
Unsigned32
380 hex + node ID
Unsigned8
FE hex
Unsigned16
0
Unsigned8
0
Unsigned16
0
Unsigned8
5
Commissioning Manual, 11/2017, 6SL3097-4AA00-0BP3
SDO ac-
cess
ro
rw
rw
rw
rw
rw
ro
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
ro
CANopen interface