Fine Adjustment Value Setting

6.6.4.1

Fine Adjustment Value Setting Operation Example

Power OFF
< 0 > S H U T D O W N
< 1 > D I A G N O S T I C
< 2 > M O D E
< 3 > P A R A M E T E R
< 4 > A D J U S T
F E E D
A D J .
X
A D J U S T
A D J U S T
T O N E
T H R E S H O L D < R > 1 . 0 V
T H R E S H O L D < T > 1 . 4 V
[FEED] [POWER]
[PAUSE]
[PAUSE]
S E T T I N G
[PAUSE]
S E T
[PAUSE]
S E T
[POWER]
+ 0 . 0 m m
[POWER]
+ 0 . 0 m m
[POWER]
+ 0
[POWER]
[POWER]
[POWER]
(1) Power off state
(2) While holding down the [FEED] key, press the
[POWER] key to turn the power on.
(3) System mode menu display (Shutdown)
(4) Press the [PAUSE] key.
(5) System mode menu display (Self-test)
(6) Press the [PAUSE] key.
(7) System mode menu display (Mode setting)
(8) Press the [PAUSE] key.
(9) System mode menu display
(Parameter setting)
(10) Press the [PAUSE] key.
(11) System mode menu display
(Fine adjustment value setting)
(12) Press the [POWER] key.
(13) Feed amount fine adjustment setting
(14) Press the [POWER] key.
(15) X-coordinate fine adjustment setting
(16) Press the [POWER] key.
(17) Print tone fine adjustment setting
(18) Press the [POWER] key.
(19) Reflective
sensor
adjustment setting
(20) Press the [POWER] key.
(21) Transmissive sensor manual threshold fine
adjustment setting
(22) Press the [POWER] key.
- 101 -