Comm. And Options - Trane TR150 Programming Manual

Hide thumbs Also See for TR150:
Table of Contents

Advertisement

Parameter Lists

5.1.9 8-** Comm. and Options

Par. No. #
Parameter description
8-0* General Settings
8-01
Control site
8-02
Control source
8-03
Control timeout time
8-04
Control timeout function
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
Baud rate
8-33
Parity/stop bits
8-35
Minimum response delay
8-36
Maximum response delay
8-37
Maximum inter-char delay
8-4* FC MC protocol set
8-42
PCD write configuration
8-43
PCD read configuration
8-5* Digital/Bus
8-50
Coasting select
8-51
Quick stop select
8-52
DC brake select
8-53
Start select
8-54
Reversing select
8-55
Set-up select
8-56
Preset reference select
8-7* BACnet
8-70
BACnet device instance
8-72
MS/TP maximum masters
8-73
MS/TP maximum info frames
8-74
I am service
8-75
Intialisation password
8-8* FC Port Diagnostics
8-80
Bus message count
8-81
Bus error count
8-82
Slave messages received
8-83
Slave error count
8-84
Slave messages sent
8-85
Slave timeout errors
8-88
Reset FC port diagnostics
8-9* Bus Feedback
8-94
Bus feedback 1
8-95
Bus feedback 2
BAS-SVP16B-EN
Programming Guide
Default value
[0] Digital and ctrl.word
[1] FC Port
1 s
[0] Off
[0] FC
1 N/A
ExpressionLimit
ExpressionLimit
0.01 s
ExpressionLimit
0.025 s
[0] None
[0] None
[3] Logic OR
[3] Logic OR
ExpressionLimit
[3] Logic OR
[0] Digital input
[3] Logic OR
[3] Logic OR
1 N/A
127 N/A
1 N/A
[0] Send at power-up
[admin]
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
[0] Do not reset
0 N/A
0 N/A
02/2017 All rights reserved.
2-set-up
Change
Conversion
during
operation
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
Type
index
Uint8
Uint8
-1
Uint16
Uint8
5
Uint8
0
Uint8
Uint8
Uint8
-3
Uint16
-3
Uint16
-3
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
0
Uint32
0
Uint8
0
Uint16
-
Uint8
0
VisStr[21]
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
-
Uint8
0
Int16
0
Int16
109
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr170

Table of Contents