Programming

2 Programming
2
2

2.1 Introduction

The frequency converter can be programmed from the LCP
or from a PC via the RS485 COM port by installing the
Trane Drive Utility (TDU). Refer to chapter 1.5 Additional
Resources for more details about the software.

2.2 Local Control Panel (LCP)

The keypad is divided into 4 functional sections.
A. Display
B. Menu key
C. Navigation keys and indicator lights
D. Operation keys and indicator lights
Illustration 2.1 Keypad
A. Display
The LCD-display is illuminated with 2 alphanumeric lines.
All data is displayed on the keypad.
Illustration 2.1 describes the information that can be read
from the display.
8
TR150 and TR170
1
Parameter number and name.
2
Parameter value.
Set-up number shows the active set-up and the edit set-up.
If the same set-up acts as both active and edit set-up, only
that set-up number is shown (factory setting). When active
3
and edit set-up differ, both numbers are shown in the
display (set-up 12). The number flashing, indicates the edit
set-up.
Motor direction is shown to the bottom left of the display –
4
indicated by a small arrow pointing either clockwise or
counterclockwise.
The triangle indicates if the keypad is in Status, Quick
5
Menu, or Main Menu.
Table 2.1 Legend to Illustration 2.1, Part I
B. Menu key
Press [Menu] to select among Status, Quick Menu, or Main
Menu.
C. Navigation keys and indicator lights
6
Com. LED: Flashes during bus communication.
7
Green LED/On: Control section is working correctly.
8
Yellow LED/Warn.: Indicates a warning.
9
Flashing Red LED/Alarm: Indicates an alarm.
[Back]: For moving to the previous step or layer in the
10
navigation structure.
[
] [
11
parameters, and within parameters. They can also be used
for setting local reference.
[OK]: For selecting a parameter and for accepting changes
12
to parameter settings.
Table 2.2 Legend to Illustration 2.1, Part II
D. Operation keys and indicator lights
[Hand On]: Starts the motor and enables control of the
frequency converter via the keypad.
NOTICE
[2] Coast inverse is the default option for
13
parameter 5-12 Terminal 27 Digital Input. If there is
no 24 V supply to terminal 27, [Hand On] does not
start the motor. Connect terminal 12 to terminal 27.
[Off/Reset]: Stops the motor (Off). If in alarm mode, the
14
alarm is reset.
[Auto On]: The frequency converter is controlled either via
15
control terminals or serial communication.
Table 2.3 Legend to Illustration 2.1, Part III