Sign In
Upload
Manuals
Brands
Trane Manuals
Controller
Tracer VV550
Trane Tracer VV550 VAV LonTalk Controller Manuals
Manuals and User Guides for Trane Tracer VV550 VAV LonTalk Controller. We have
2
Trane Tracer VV550 VAV LonTalk Controller manuals available for free PDF download: Installation, Operation And Maintenance Manual, Installation Manual
Trane Tracer VV550 Installation, Operation And Maintenance Manual (110 pages)
VAV Controller
Brand:
Trane
| Category:
Controller
| Size: 3 MB
Table of Contents
Table of Contents
3
Overview
6
Supported and Non-Supported Equipment
6
Supported Equipment
6
Non-Supported Equipment
7
Features and Specifications
7
Features
7
Specifications
8
Inputs and Outputs
9
Comm5 Communications
9
Comm5 Communications Link
10
Rover Service Tool
10
Binary Input
11
Occupancy Binary Input
11
Generic Binary Input
11
Not Used Input
11
Occupancy and Generic Binary Input Configuration
12
Analog Inputs
12
Space Temperature Analog Input
13
Space Setpoint Analog Input
14
Primary Air Temperature/Discharge Air Temperature Analog Input
15
Primary Airflow (Differential Pressure) Analog Input
16
Zone Sensor Inputs
18
Zone Sensor on and CANCEL Buttons
18
10K Thermistor
19
Internal and External Space Setpoint Adjustment
19
Single-Star (*) and Double-Star (**) Thumbwheel Settings
21
Binary Outputs
22
Primary Air Valve Binary Outputs
22
Heat and Fan Binary Outputs
22
Binary Output Overrides
22
Analog Output
23
Sequence of Operations
23
Control Modes
24
Control Sequences
26
Power-Up/Reset Sequence
26
Manufacturing Test
27
Unit Shutdown
27
Emergency Override
27
Manual Output Test
28
Auto-Commissioning Test Sequence
29
Calibration Sequence
31
Overrides: Water Valve, Flow, Fan
32
Normal Operation
33
Occupancy
34
Occupancy Modes
34
Space Setpoint Operation
36
Occupancy Mode Sources
36
Determining the Occupancy Mode
37
Overriding Occupancy
38
Occupancy Arbitration
39
Space Temperature Control Mode
40
Heating or Cooling Control Mode Operation
41
Initial Space Demand Determination for Space Temperature Control
41
Heating and Cooling Changeover Logic
42
Cooling Operation
43
Heating Operation
44
Air Valve Control in Space Temperature Control Operation
45
Reheat Control
45
Morning Warm-Up
49
Pre-Cool (Morning Cool Down)
50
Maximum Flow Heat
51
Night Purge
51
Ventilation Control
52
Unoccupied Space Temperature Control
63
Fan Control
64
Ventilation Flow Control Mode
66
Air Valve Control
67
Staged Reheat Control (Electric and Hot Water)
67
Modulating Reheat Control (Hot Water Only)
68
Freeze Protection (Hot Water Only)
68
Morning Warm-Up
69
Pre-Cool (Morning Cool Down)
69
Maximum Flow Heat
69
Night Purge
69
Construction (Temporary Heat)
69
Humidity Control Functions
69
Unoccupied Ventilation Flow Control
70
Fan Control
70
Flow Tracking Control Mode
70
Air Valve Control in Flow Tracking Control Operation
71
Reheat Control in Flow Tracking Control Operation
71
Unoccupied Flow Tracking Control
71
Morning Warm-Up
72
Pre-Cool (Morning Cool Down)
72
Night Purge
72
Construction (Temporary Heat)
72
Humidity Control Functions
72
Fan Control
72
Stand-Alone Control
72
Air Balance Functions
73
Zone Sensor Air Balance Function
73
Communicating Air Balance Function
74
Analog Input Calibration
75
Configuration
76
Configuration Considerations
76
Parameter Configurations
76
Location Identifier
77
Operation Without Configuration
77
Application Information
78
Troubleshooting
79
LED Operation
79
Red Service LED
79
Service Push Button
79
Green Status LED
80
Yellow Comm LED
80
Manual Output Test
80
Diagnostics
81
Resetting Diagnostics
83
Manual Output Test
84
Cycling Power
84
Building Automation System
84
Rover™ Service Tool
84
Questionable Unit Operation
84
Appendix A: Properties, Data Lists Points, and Network Variables
87
Appendix B: Tracer Summit™ BAS Present Value Chart
92
Appendix C: Mode Control Operation
93
Appendix D: Reheat Actuation Schedule Tables
97
Effect of Communicated Auxiliary Heat Enable on Reheat
98
Reheat Actuation Schedule with no Fan Present
102
Reheat Actuation Schedule with Parallel Fan Present
105
Index
107
Advertisement
Trane Tracer VV550 Installation Manual (12 pages)
VAV Controllers
Brand:
Trane
| Category:
Controller
| Size: 0 MB
Table of Contents
Introduction
2
Table of Contents
3
Features and Benefits
4
Automatic Calibration
4
Ventilation Flexibility
4
Flow Tracking
4
Ventilation Flow Control with Tempering
4
Local Versus Remote Reheat Flexibility
4
Occupied and Unoccupied Operation
4
Timed Override
4
Service Pin from the Trane Zone Sensor
4
Auto-Commissioning Sequence
5
Manual Test Function
5
Drive Minimum and Maximum from Zone Sensor
5
Trane Controller Compatibility
5
Interoperability
5
Wiring Diagram
5
Wiring Diagram for Tracer VV550/551 VAV
6
Controllers
6
Network Architecture
7
Zone Sensor Options
8
Dimensions and Specifications
9
Power Requirements
9
Operating Environment
9
Storage Environment
9
Dimensions
9
Weight with Enclosure (Tracer VV551)
9
Analog Inputs
9
Binary Input
9
Binary Outputs
9
Agency Listings/Compliance
9
Data Lists
11
Advertisement
Related Products
Trane VariTrane VAV-SVX02B-EN
Trane Tracer VV551
Trane VAV VV550 LonTalk
Trane TRACER CH532
Trane Tracer ZN.520
Trane Tracer ZN524
Trane Tracer ZN521
Trane Tracer AH540
Trane Tracer AH541
Trane Tracer ZN517
Trane Categories
Air Conditioner
Heat Pump
Chiller
Air Handlers
Furnace
More Trane Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL