Acoustic Noise Ratings; Selected Options; Vlt ® General Purpose I/O Module Mcb - Danfoss VLT Refrigeration Drive FC 103 Design Manual

1.1-90 kw
Hide thumbs Also See for VLT Refrigeration Drive FC 103:
Table of Contents

Advertisement

Specifications
Mains
Rise time
Cable
voltage
length [m]
[V]
[μsec]
36
400
0.232
100
400
0.410
150
400
0.430
Table 7.33 Frequency Converter, P22K, T4
Mains
Cable
voltage
Rise time
length [m]
[V]
[μsec]
15
400
0.271
100
400
0.440
150
400
0.520
Table 7.34 Frequency Converter, P30K, T4
Mains
Cable
voltage
Rise time
length [m]
[V]
[μsec]
5
480
0.270
50
480
0.435
100
480
0.840
150
480
0.940
Table 7.35 Frequency Converter, P37K, T4
Mains
Rise time
Cable
voltage
length [m]
[V]
[μsec]
36
400
0.254
50
400
0.465
100
400
0.815
150
400
0.890
Table 7.36 Frequency Converter, P45K, T4
Mains
Cable
voltage
Rise time
length [m]
[V]
[μsec]
10
400
0.350
Table 7.37 Frequency Converter, P55K, T4
Mains
Cable
voltage
Rise time
length [m]
[V]
[μsec]
5
480
0.371
Table 7.38 Frequency Converter, P75K, T4
Mains
Cable
voltage
Rise time
length [m]
[V]
[μsec]
5
400
0.364
Table 7.39 Frequency Converter, P90K, T4
MG16G202
Design Guide
dU/dt
U
PEAK
[kV]
[kV/μsec]
0.950
3.534
0.980
1.927
0.970
1.860
U
dU/dt
PEAK
[kV]
[kV/μsec]
1.000
3.100
1.000
1.818
0.990
1.510
U
dU/dt
PEAK
[kV]
[kV/μsec]
1.276
3.781
1.184
2.177
1.188
1.131
1.212
1.031
dU/dt
U
PEAK
[kV]
[kV/μsec]
1.056
3.326
1.048
1.803
1.032
1.013
1.016
0.913
U
dU/dt
PEAK
[kV]
[kV/μsec]
0.932
2.130
U
dU/dt
PEAK
[kV]
[kV/μsec]
1.170
2.466
U
dU/dt
PEAK
[kV]
[kV/μsec]
1.030
2.264
Danfoss A/S © 08/2015 All rights reserved.

7.11 Acoustic Noise Ratings

The typical values measured at a distance of 1 m from the
unit:
At reduced fan speed
Enclosure size
(50%) [dBA]
A2
51
A3
51
A4
50
A5
54
B1
61
B2
58
B3
59.4
B4
53
C1
52
C2
55
C3
56.4
C4
Table 7.40 Measured Values

7.12 Selected Options

7.12.1 VLT
®
General Purpose I/O Module
MCB 101
MCB 101 is used for extension of digital and analog inputs
and outputs.
Fit the MCB 101 into slot B of the frequency converter.
Contents:
MCB 101 option module
Extended fixture for LCP
Terminal cover
MCB 101
General Purpose I/O
SW. ver. XX.XX
X30/
1
2
3
4
5
6
Illustration 7.4 MCB 101 Option
Full fan speed [dBA]
60
60
55
63
67
70
70.5
62.8
62
65
67.3
FC Series
B slot
Code No. 130BXXXX
7
8
9
10
11
12
135
7
7

Advertisement

Table of Contents
loading