Specifications
Cable
length [m]
30
100
150
Table 7.21 Frequency Converter, P15K, T2
Cable
length [m]
36
136
150
Table 7.22 Frequency Converter, P18K, T2
7
7
Cable
length [m]
36
136
150
Table 7.23 Frequency Converter, P22K, T2
Cable
length [m]
15
50
150
Table 7.24 Frequency Converter, P30K, T2
Cable
length [m]
30
100
150
Table 7.25 Frequency Converter, P37K, T2
Cable
length [m]
30
100
150
Table 7.26 Frequency Converter, P45K, T2
134
Mains
Rise time
voltage
U
PEAK
[V]
[μsec]
[kV]
240
0.556
0.650
240
0.592
0.594
240
0.708
0.575
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
240
0.244
0.608
240
0.568
0.580
240
0.720
0.574
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
240
0.244
0.608
240
0.560
0.580
240
0.720
0.574
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
240
0.194
0.626
240
0.252
0.574
240
0.444
0.538
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
240
0.300
0.598
240
0.536
0.566
240
0.776
0.546
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
240
0.300
0.598
240
0.536
0.566
240
0.776
0.546
Danfoss A/S © 08/2015 All rights reserved.
®
VLT
Refrigeration Drive FC 103
380–480 V (T4)
dU/dt
[kV/μsec]
Cable
0.935
length [m]
0.807
5
0.669
50
150
Table 7.27 Frequency Converter, P1K5, T4
dU/dt
[kV/μsec]
Cable
1.993
length [m]
0.832
5
0.661
50
150
Table 7.28 Frequency Converter, P4K0, T4
dU/dt
[kV/μsec]
Cable
1.993
length [m]
0.832
5
0.661
50
150
Table 7.29 Frequency Converter, P7K5, T4
dU/dt
[kV/μsec]
Cable
2.581
length [m]
1.929
15
0.977
100
150
Table 7.30 Frequency Converter, P11K, T4
dU/dt
[kV/μsec]
Cable
1.593
length [m]
0.843
36
0.559
100
150
Table 7.31 Frequency Converter, P15K, T4
dU/dt
[kV/μsec]
Cable
1.593
length [m]
0.843
36
0.559
100
150
Table 7.32 Frequency Converter, P18K, T4
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
400
0.640
0.690
400
0.470
0.985
400
0.760
1.045
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
400
0.172
0.890
400
0.310
–
400
0.370
1.190
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
400
0.04755
0.739
400
0.207
1.040
400
0.6742
1.030
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
400
0.408
0.718
400
0.364
1.050
400
0.400
0.980
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
400
0.422
1.060
400
0.464
0.900
400
0.896
1.000
Mains
voltage
Rise time
U
PEAK
[V]
[μsec]
[kV]
400
0.344
1.040
400
1.000
1.190
400
1.400
1.040
dU/dt
[kV/μsec]
0.862
0.985
0.947
dU/dt
[kV/μsec]
4.156
2.564
1.770
dU/dt
[kV/μsec]
8.035
4.548
2.828
dU/dt
[kV/μsec]
1.402
2.376
2.000
dU/dt
[kV/μsec]
2.014
1.616
0.915
dU/dt
[kV/μsec]
2.442
0.950
0.596
MG16G202