Manual Mig/Mag Parameters Setting (1St Level): Inductance Setting; Manual Mig/Mag Parameters Setting (2Nd Level) - Weco WF-104 Instruction Manual

Hide thumbs Also See for WF-104:
Table of Contents

Advertisement

WF-104
WF-108
Welding
HOLD function
(At welding end)

10.2.1 Manual MIG/MAG parameters setting (1st level): inductance setting.

○ Using the encoder E3
B
The value is saved automatically.
IND: This parameter allows electronic adjust-
ment of the welding inductance from the main
menu.

10.2.2 MANUAL MIG/MAG PARAMETERS SETTING (2ND LEVEL)

C
○ Press the button S7
D
○ Scroll down the list of parameters to be edited by pressing buttons S5
○ Using the encoder E3
B
The value is saved automatically.
Tab. 6 - 2nd level menu parameters in MANUAL MIG/MAG mode
PROCEDURE
INDUCTANCE
PRE GAS
SOFT START
BURN BACK
2 STROKE
2 STROKE SPOT
POST GAS
SPOT TIME
INDUCTANCE
PRE GAS
SOFT START
4 STROKE
BURN BACK
POST GAS
WELD THE WORLD
Shows the average current meas-
ured during welding.
Shows the average current
measured during the last welding
procedure performed.
, edit the value of the selected parameter
to enter the 2nd level menu.
, edit the value of the selected parameter
PARAMETER
MIN
(row 1/6)
1
(row 2/6)
0.0 s
(row 3/6)
1 %
(row 4/6)
1 %
(row 5/6)
0.0 s
(row 6/6)
0.1 s
(row 1/5)
1
(row 2/5)
0.0 s
(row 3/5)
1 %
(row 4/5)
1 %
(row 5/5)
0.0 s
Shows the average voltage measured
during welding.
Shows the average voltage measured
during the last welding procedure per-
formed.
SHORT/SPRAY
IND
100
DEFAULT
MAX
100
200
0.0 s
10.0 s
35 %
100 %
25 %
200 %
1.0 s
10.0 s
The parameter value is saved for each
OFF
25.0 s
100
200
0.0 s
10.0 s
35 %
100 %
25 %
200 %
1.0 s
10.0 s
Cod. 006.0001.0940
16/04/2018 V.2.25
ENGLISH
Shows "---".
Shows "---".
MAN
and S6
NOTES
welding mode.
43