Communication-Specific Accessories - Endress+Hauser Proline Prosonic Flow 91W Technical Information

Ultrasonic flow measuring system. flowrate measurement for standard applications with drinking water and process water.
Hide thumbs Also See for Proline Prosonic Flow 91W:
Table of Contents

Advertisement

Proline Prosonic Flow 91W
Communication-specific
accessories
Endress+Hauser
Accessory
Description
Conduit adapter for
Prosonic Flow W (DN 15 to 65, ½" to 2 ½")
connecting cable
• Conduit adapter incl. cable entry M20 × 1,5
• Conduit adapter incl. cable entry ½" NPT
• Conduit adapter incl. cable entry G ½"
Prosonic Flow W (DN 50 to 4000, 2" to 160")
• Conduit adapter incl. cable entry M20 × 1,5
• Conduit adapter incl. cable entry ½" NPT
• Conduit adapter incl. cable entry G ½"
Connecting cable
For sensor DN 15 to 65, ½" to 2 ½"
5 m (16 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
10 m (33 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
15 m (49 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
30 m (98 ft) sensor cable, TPE-V, –20 to +70 °C (–4 to 158 °F)
For sensor DN 50 to 4000, 2" to 160"
5 m (16 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
10 m (33 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
15 m (49 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
30 m (98 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
60 m (197 ft) sensor cable, PVC, –20 to +70 °C (–4 to 158 °F)
Acoustic coupling fluid
• Coupling fluid 0 to 170 °C (+32 to 338 °F), Standard
• Adhesive coupling fluid –40 to +80 °C (–40 to 176 °F)
• Water-soluble coupling fluid –20 to +80 °C (–4 to 176 °F)
• Coupling fluid DDU 19, –20 to +60 °C (–4 to 140 °F)
• Coupling fluid –40 to +100 °C (–40 to 212 °F), Standard,
Accessory
Description
HART Communicator
Handheld terminal for remote configuration and for obtaining
Field Xpert SFX 100
measured values via the HART current output (4 to 20 mA).
Contact your Endress+Hauser representative for more
information.
Fieldgate FXA320
Gateway for remote interrogation of HART sensors and actuators
via Web browser:
• 2-channel analog input (4 to 20 mA)
• 4 binary inputs with event counter function and frequency
measurement
• Communication via modem, Ethernet or GSM
• Visualization via Internet/Intranet in the Web browser and/or
WAP cellular phone
• Limit value monitoring with alarm signaling via e-mail or SMS
• Synchronized time stamping of all measured values.
Fieldgate FXA520
Gateway for remote interrogation of HART sensors and actuators
via Web browser:
• Web server for remote monitoring of up to 30 measuring points
• Intrinsically safe version [EEx ia]IIC for applications in
hazardous areas
• Communication via modem, Ethernet or GSM
• Visualization via Internet/Intranet in the Web browser and/or
WAP cellular phone
• Limit value monitoring with alarm signaling via e-mail or SMS
• Synchronized time stamping of all measured values
• Remote diagnosis and remote configuration of
connected HART devices
FXA195
The Commubox FXA195 connects intrinsically safe Smart
transmitters with HART protocol to the USB port of a personal
computer. This makes the remote operation of the transmitters
possible with the aid of configuration programs (e.g. FieldCare).
Power is supplied to the Commubox by means of the USB port
type MBG2000
Order code
DK9CB - AA1
DK9CB - AA2
DK9CB - AA3
DK9CB - AB1
DK9CB - AB2
DK9CB - AB3
DK9SS - AAA
DK9SS - AAB
DK9SS - AAC
DK9SS - AAD
DK9SS - ABA
DK9SS - ABB
DK9SS - ABC
DK9SS - ABD
DK9SS - ABJ
DK9CM - 2
DK9CM - 3
DK9CM - 4
DK9CM - 6
DK9CM - 7
Order code
SFX100 – *******
FXA320 - *****
FXA520 - ****
FXA195 – *
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents