Sign In
Upload
Manuals
Brands
Endress+Hauser Manuals
Measuring Instruments
Proline Promass O 100
Endress+Hauser Proline Promass O 100 Manuals
Manuals and User Guides for Endress+Hauser Proline Promass O 100. We have
2
Endress+Hauser Proline Promass O 100 manuals available for free PDF download: Operating Instructions Manual
Endress+Hauser Proline Promass O 100 Operating Instructions Manual (164 pages)
Coriolis Flowmeter PROFINET
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
3
About this Document
6
Document Function
6
Symbols
6
Safety Symbols
6
Electrical Symbols
6
Tool Symbols
6
Symbols for Certain Types of Information
7
Symbols in Graphics
7
Documentation
7
Registered Trademarks
8
Safety Instructions
9
Requirements for the Personnel
9
Intended Use
9
Workplace Safety
10
Operational Safety
10
Product Safety
10
Security
11
Product Description
12
Product Design
12
Device Version with PROFINET Communication Protocol
12
Incoming Acceptance and Product
13
Identification
13
Incoming Acceptance
13
Product Identification
13
Measuring Instrument Nameplate
14
Symbols on the Device
16
Storage and Transport
17
Storage Conditions
17
Transporting the Product
17
Measuring Devices Without Lifting Lugs
17
Measuring Devices with Lifting Lugs
18
Transporting with a Fork Lift
18
Packaging Disposal
18
Installation
19
Installation Requirements
19
Installation Position
19
Environmental and Process Requirements
21
Thermal Insulation
21
Special Mounting Instructions
23
Hygienic Compatibility
23
Installing the Measuring Instrument
24
Required Tools
24
Preparing the Measuring Instrument
24
Mounting the Measuring Device
24
Turning the Display Module
25
Post-Installation Check
26
Electrical Connection
27
Electrical Safety
27
Connecting Requirements
27
Required Tools
27
Requirements for Connecting Cable
27
Terminal Assignment
28
Pin Assignment, Device Plug
29
Preparing the Measuring Device
29
Connecting the Measuring Instrument
29
Connecting the Transmitter
30
Potential Equalization
31
Requirements
31
Special Connection Instructions
31
Connection Examples
31
Hardware Settings
32
Setting the Device Name
32
Ensuring the Degree of Protection
33
Post-Connection Check
34
Operation Options
35
Overview of Operation Options
35
Structure and Function of the Operating Menu
36
Structure of the Operating Menu
36
Operating Philosophy
37
Displaying the Measured Values Via the Local Display (Optionally Available)
38
Operational Display
38
User Roles and Related Access Authorization
39
Access to Operating Menu Via Web Browser
39
Function Range
39
Prerequisites
40
Computer Hardware
40
Computer Software
40
Computer Settings
40
Connecting the Device
41
Starting the Web Browser
41
Logging on
42
User Interface
43
Function Row
43
Navigation Area
43
Disabling the Web Server
44
Logging out
44
Access to the Operating Menu Via the Operating Tool
45
Connecting the Operating Tool
45
Fieldcare
46
Devicecare
47
System Integration
48
Overview of Device Description Files
48
Current Version Data for the Device
48
Operating Tools
48
Device Master File (GSD)
49
File Name of the Manufacturer-Specific Device Master File (GSD)
49
File Name of the PA Profile Device Master File (GSD)
49
Cyclic Data Transmission
50
Overview of the Modules
50
Description of the Modules
50
Digital Input Module
51
Available Units
55
Digital Output Module
56
Status Coding
58
Factory Setting
59
Startup Configuration
60
Commissioning
61
Post-Mounting and Post-Connection Check
61
Identifying the Device in the PROFINET
61
Startup Parameterization
61
Connecting Via Fieldcare
61
Setting the Operating Language
61
Configuring the Measuring Instrument
61
Defining the Tag Name
62
Setting the System Units
62
Parameter Overview with Brief Description
63
Displaying the Communication Interface
64
Selecting and Setting the Medium
66
Configuring the Low Flow Cut off
68
Configuring Partially Filled Pipe
69
Using the Parameter to Enter the Access Code
70
Advanced Settings
70
Calculated Process Variables
70
Carrying out a Sensor Adjustment
72
Density Adjustment
72
Configuring the Totalizer
76
Using Parameters for Device Administration
77
Simulation
77
Protecting Settings from Unauthorized Access
78
Write Protection Via Access Code
78
Write Protection Via Write Protection Switch
79
Write Protection Via Startup Parameterization
80
Operation
81
Reading the Device Locking Status
81
Adjusting the Operating Language
81
Configuring the Display
81
Reading off Measured Values
81
Measured Variables" Submenu
81
Endress+Hauser
83
Totalizer" Submenu
91
Adapting the Measuring Device to the Process Conditions
92
Performing a Totalizer Reset
92
Function Scope of "Control Totalizer" Parameter
94
Function Range of "Reset All Totalizers" Parameter
94
Diagnostics and Troubleshooting
95
General Troubleshooting
95
Diagnostic Information Via Leds
97
Transmitter
97
Diagnostic Information in the Web Browser
97
Diagnostic Options
97
Status Signals
98
Calling up Remedy Information
99
Diagnostic Information in Fieldcare or
99
Diagnostic Options
99
Calling up Remedy Information
100
Adapting the Diagnostic Information
100
Adapting the Diagnostic Behavior
100
Overview of Diagnostic Information
103
Diagnostic of Sensor
104
Diagnostic of Electronic
107
Diagnostic of Configuration
113
Diagnostic of Process
117
Pending Diagnostic Events
124
Diagnostics List
125
Event Logbook
125
Reading out the Event Logbook
125
Filtering the Event Logbook
126
Overview of Information Events
126
12.10 Resetting the Measuring Device
127
12.10.1 Function Range of "Device Reset" Parameter
127
12.11 Device Information
128
12.12 Firmware History
129
Maintenance
130
Maintenance Work
130
Exterior Cleaning
130
Measuring and Test Equipment
130
Endress+Hauser Services
130
Repair
131
General Notes
131
Repair and Conversion Concept
131
Notes for Repair and Conversion
131
Spare Parts
131
Endress+Hauser Services
131
Return
131
Disposal
132
Removing the Measuring Device
132
Disposing of the Measuring Device
132
Accessories
133
Device-Specific Accessories
133
For the Sensor
133
Communication-Specific Accessories
133
Service-Specific Accessories
134
System Components
134
Technical Data
135
Application
135
Function and System Design
135
Input
136
Direct Measured Variables
136
Output
137
Endress+Hauser
139
Power Supply
141
Performance Characteristics
142
Mass Flow and Volume Flow (Liquids)
143
Zero Point Stability
143
Mounting
146
Mounting Requirements
146
Environment
146
Process
147
Pressure-Temperature Ratings
147
16.10 Mechanical Construction
150
Sensor Housing
151
Measuring Tubes
151
16.11 Operability
152
Display Element
152
16.12 Certificates and Approvals
154
16.13 Application Packages
155
Heartbeat Verification
156
Heartbeat Monitoring
156
16.14 Accessories
157
16.15 Supplementary Documentation
157
Technical Information
157
Special Documentation
158
Installation Instructions
158
Index
159
Advertisement
Endress+Hauser Proline Promass O 100 Operating Instructions Manual (127 pages)
Coriolis Flowmeter Modbus RS485
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
About this Document
6
Document Function
6
Symbols for Certain Types of Information
7
Symbols in Graphics
7
Registered Trademarks
8
Safety Instructions
9
Requirements for the Personnel
9
Intended Use
9
Workplace Safety
10
Operational Safety
10
Product Safety
10
Product Description
12
Product Design
12
Incoming Acceptance and Product Identification
13
Transmitter Nameplate
14
Sensor Nameplate
15
Symbols on the Device
16
Storage and Transport
17
Storage Conditions
17
Transporting the Product
17
Measuring Devices with Lifting Lugs
18
Transporting with a Fork Lift
18
Packaging Disposal
18
Installation Requirements
19
Installation Position
19
Thermal Insulation
21
Special Mounting Instructions
23
Post-Installation Check
25
Electrical Connection
27
Electrical Safety
27
Terminal Assignment
28
Pin Assignment, Device Plug
31
Supply Voltage
31
Signal Transmission
31
Connecting the Transmitter
33
Potential Equalization
35
Special Connection Instructions
35
Connection Examples
35
Hardware Settings
36
Ensuring the Degree of Protection
37
Post-Connection Check
37
Overview of Operation Options
39
Structure and Function of the Operating Menu
40
Operating Philosophy
41
Operational Display
41
User Roles and Related Access Authorization
43
Access to the Operating Menu Via the Operating Tool
44
User Interface
45
Device Care
45
System Integration
46
Register Information
47
Modbus Data Map
49
Scan List Configuration
49
Connecting Via Fieldcare
51
Setting the Operating Language
51
Parameter Overview with Brief Description
52
Setting the System Units
52
Selecting and Setting the Medium
55
Configuring the Low Flow Cut off
58
Advanced Settings
60
Carrying out a Sensor Adjustment
62
Density Adjustment
62
Configuring the Totalizer
66
Using Parameters for Device Administration
67
Protecting Settings from Unauthorized Access
68
Write Protection Via Write Protection Switch
68
Operation
70
Endress+Hauser
71
"Totalizer" Submenu
79
Adapting the Measuring Device to the Process Conditions
80
Performing a Totalizer Reset
80
Function Scope of "Control Totalizer" Parameter
82
Diagnostics and Troubleshooting
84
General Troubleshooting
84
Diagnostic Options
86
Calling up Remedy Information
87
Reading out Diagnostic Information
87
Configuring Error Response Mode
87
Adapting the Diagnostic Information
88
Adapting the Diagnostic Behavior
88
Overview of Diagnostic Information
88
Pending Diagnostic Events
90
Diagnostics List
91
Reading out the Event Logbook
91
Filtering the Event Logbook
92
Overview of Information Events
92
Resetting the Measuring Device
93
Device Information
94
Firmware History
95
Maintenance Work
96
Exterior Cleaning
96
Measuring and Test Equipment
96
Endress+Hauser Services
96
General Notes
97
Spare Parts
97
Removing the Measuring Device
98
Disposing of the Measuring Device
98
Device-Specific Accessories
99
For the Sensor
99
Communication-Specific Accessories
99
Service-Specific Accessories
100
System Components
100
Technical Data
101
Function and System Design
101
Direct Measured Variables
102
Light Emitting Diodes (LED)
104
Protocol-Specific Data
104
Power Supply
104
Performance Characteristics
106
Reference Operating Conditions
106
Design Fundamentals
106
Zero Point Stability
107
Flow Values
107
Accuracy of Outputs
107
Pressure-Temperature Ratings
111
Flow Limit
112
Mechanical Construction
113
Certificates and Approvals
115
Application Packages
117
Heartbeat Monitoring
118
Supplementary Documentation
119
Technical Information
119
Special Documentation
120
Installation Instructions
120
Advertisement
Related Products
Endress+Hauser OUM980
Endress+Hauser OUSAF21
Endress+Hauser ORIA15
Endress+Hauser OUSAF44
Endress+Hauser Proline Prowirl O 200
Endress+Hauser OL3318-14-200
Endress+Hauser PROline prosonic flow Clamp On 90P
Endress+Hauser PROline prosonic flow Clamp On 90U
Endress+Hauser PROline Prosonic Flow Clamp On 93P
Endress+Hauser Prosonic Flow Clamp On 93W
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL