Cable-Specification; Power Consumption; Power Supply Failure; Potential Equalization - Endress+Hauser Proline Prosonic Flow 91W Technical Information

Ultrasonic flow measuring system. flowrate measurement for standard applications with drinking water and process water.
Hide thumbs Also See for Proline Prosonic Flow 91W:
Table of Contents

Advertisement

Proline Prosonic Flow 91W

Cable-specification

!

power consumption

Power supply failure

Potential equalization

Endress+Hauser
Cable gland for two connection cables (2 × Q 4 mm/0.16") per cable entry
Only use the connection cable supplied by Endress+Hauser. Different versions of the connecting cables are
available  ä 21.
Prosonic Flow
• Cable material:
– Prosonic Flow 91W (DN 50 to 4000/ 2" to 160") PVC (standard) or optional PTFE
– Prosonic Flow 91W (DN 15 to 65 / ½" to 2½") TPE-V
• Cable length:
– For use in a non hazardous zone: 5 to 60 m (16.4 to 196.8 ft)
Note!
To ensure correct measuring results, route the connection cable well clear of electrical machines and switching
elements.
85 to 250 V AC: <12 VA (incl. measuring sensor)
20 to 28 V AC: <7 VA (incl. measuring sensor)
11 to 40 V DC: <5 W (incl. measuring sensor)
Lasting min. 1 power cycle
HistoROM/T-DAT save measuring system data if the power supply fails
For potential equalization, no special measures are necessary.
A0008152
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents