Sign In
Upload
Manuals
Brands
Endress+Hauser Manuals
Measuring Instruments
Proline Promag H 100 HART
Endress+Hauser Proline Promag H 100 HART Manuals
Manuals and User Guides for Endress+Hauser Proline Promag H 100 HART. We have
1
Endress+Hauser Proline Promag H 100 HART manual available for free PDF download: Operating Instructions Manual
Endress+Hauser Proline Promag H 100 HART Operating Instructions Manual (128 pages)
Electromagnetic flowmeter
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
3
About this Document
6
Document Function
6
Symbols Used
6
Safety Symbols
6
Electrical Symbols
6
Tool Symbols
6
Symbols for Certain Types of Information
7
Symbols in Graphics
7
Documentation
7
Standard Documentation
8
Supplementary Device-Dependent Documentation
8
Registered Trademarks
8
Basic Safety Instructions
9
Requirements for the Personnel
9
Designated Use
9
Workplace Safety
10
Operational Safety
10
Product Safety
10
Security
11
Product Description
12
Product Design
12
Device Version with HART Communication Type
12
4 Incoming Acceptance and Product
13
Identification
13
Incoming Acceptance
13
Product Identification
13
Transmitter Nameplate
14
Sensor Nameplate
15
Symbols on Measuring Device
16
Storage and Transport
17
Storage Conditions
17
Transporting the Product
17
Measuring Devices Without Lifting Lugs
17
Measuring Devices with Lifting Lugs
18
Transporting with a Fork Lift
18
Packaging Disposal
18
Installation
19
Installation Conditions
19
Mounting Position
19
Inlet and Outlet Runs
20
Requirements from Environment and Process
21
Ambient Temperature Range
21
Mounting the Measuring Device
23
Required Tools
23
Preparing the Measuring Device
23
Mounting the Sensor
23
Turning the Display Module
24
Post-Installation Check
25
Electrical Connection
26
Electrical Safety
26
Connecting Requirements
26
Required Tools
26
Requirements for Connection Cable
26
Terminal Assignment
27
Pin Assignment, Device Plug
28
Supply Voltage
28
Preparing the Measuring Device
28
Connecting the Device
29
Connecting the Transmitter
29
Ensuring Potential Equalization
31
Requirements
31
Connection Example, Standard Scenario
31
Connection Example in Special Situations
31
Special Connection Instructions
33
Connection Examples
33
Pulse/Frequency Output
34
Switch Output
34
HART Input
34
Ensuring the Degree of Protection
35
Post-Connection Check
35
Operation Options
37
Overview of Operating Options
37
Structure and Function of the Operating Menu
38
Structure of the Operating Menu
38
Operating Philosophy
39
Access to the Operating Menu Via the Web Browser
40
Function Range
40
Prerequisites
40
Establishing a Connection
41
Starting the Web Browser
41
Endress+Hauser
41
Logging on
42
User Interface
43
Function Row
43
Disabling the Web Server
44
Logging out
44
Access to the Operating Menu Via the Operating Tool
45
Connecting the Operating Tool
45
Field Xpert SFX350, SFX370
46
Fieldcare
46
Function Scope
46
Devicecare
48
AMS Device Manager
48
Simatic Pdm
48
Field Communicator 475
48
System Integration
49
Overview of Device Description Files
49
Current Version Data for the Device
49
Operating Tools
49
Measured Variables Via HART Protocol
49
Device Variables
50
Other Settings
51
Burst Mode Functionality in Accordance with HART 7
51
Specification
51
Parameter Overview with Brief Description
52
Commissioning
53
Function Check
53
Connecting Via Fieldcare
53
Setting the Operating Language
53
Configuring the Measuring Device
53
Defining the Tag Name
54
Device Tag
54
Configuring the Current Output
55
Current Output 1
55
Configuring the Pulse/Frequency
56
Switch Output
56
Pulse/Frequency/Switch Output 1
56
Configuring the Local Display
62
Display
62
Configuring the Output Conditioning
63
Output Conditioning
64
Configuring the Low Flow Cut off
65
Low Flow Cut off
65
Configuring Empty Pipe Detection
67
Configuring the HART Input
67
Empty Pipe Detection
67
HART Input
67
Advanced Settings
70
Setting the System Units
70
Advanced Setup
70
Carrying out a Sensor Adjustment
72
Configuring the Totalizer
72
Carrying out Additional Display Configurations
74
Performing Electrode Cleaning
76
Using Parameters for Device Administration
77
Simulation
78
Protecting Settings from Unauthorized Access
80
Write Protection Via Access Code
80
Write Protection Via Write Protection Switch
80
Operation
82
Reading the Device Locking Status
82
Reading Measured Values
82
Process Variables" Submenu
82
Totalizer" Submenu
83
Output Values
84
Adapting the Measuring Device to the Process Conditions
85
Performing a Totalizer Reset
85
Function Scope of the "Control Totalizer" Parameter
86
Function Scope of the "Reset All Totalizers" Parameter
86
Diagnostics and Troubleshooting
87
General Troubleshooting
87
Diagnostic Information Via Light Emitting Diodes
88
Transmitter
88
Diagnostic Information in the Web Browser
89
Diagnostic Options
89
Status Signals
89
Calling up Remedy Information
90
Diagnostic Information in Devicecare or
90
Fieldcare
90
Diagnostic Options
90
Calling up Remedy Information
91
Adapting the Diagnostic Information
92
Adapting the Diagnostic Behavior
92
Adapting the Status Signal
92
Overview of Diagnostic Information
93
Pending Diagnostic Events
95
Diagnostic List
96
Event Logbook
96
Reading out the Event Logbook
96
Filtering the Event Logbook
97
Overview of Information Events
97
12.10 Resetting the Measuring Device
98
12.10.1 Function Scope of the "Device Reset" Parameter
98
12.11 Device Information
98
12.12 Firmware History
101
Maintenance
102
Maintenance Tasks
102
Exterior Cleaning
102
Interior Cleaning
102
Replacing Seals
102
Measuring and Test Equipment
102
Endress+Hauser Services
102
Repairs
103
General Notes
103
Repair and Conversion Concept
103
Notes for Repair and Conversion
103
Spare Parts
103
Endress+Hauser Services
103
Return
103
Disposal
104
Removing the Measuring Device
104
Disposing of the Measuring Device
104
Accessories
105
Device-Specific Accessories
105
For the Transmitter
105
For the Sensor
105
Communication-Specific Accessories
105
Service-Specific Accessories
106
System Components
107
Technical Data
108
Application
108
Function and System Design
108
Input
108
Output
110
Current Output
110
Local Display
112
Light Emitting Diodes (LED)
112
Power Supply
113
Performance Characteristics
114
Installation
115
Environment
115
Interior Cleaning
116
Process
116
Pressure-Temperature Ratings
117
Flow Limit
117
16.10 Mechanical Construction
118
16.11 Operability
118
16.12 Certificates and Approvals
120
Sanitary Compatibility
120
16.13 Application Packages
121
16.14 Accessories
122
16.15 Supplementary Documentation
122
Index
124
Advertisement
Advertisement
Related Products
Endress+Hauser Proline Promag H 100 EtherNet/IP
Endress+Hauser Proline Promag H 10
Endress+Hauser Proline Promag H 500
Endress+Hauser HART Proline Promass 83
Endress+Hauser HART Proline Promag 51
Endress+Hauser HART Proline Promass 80
Endress+Hauser Analytikjena SELECT Head 8/50 ml
Endress+Hauser Analytikjena SELECT Head 8/250 ml
Endress+Hauser HART
Endress+Hauser Proline Promag H 300
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL