Applicable System - Mitsubishi Q Series User Manual

Positioning module, programmable logic controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

2 SYSTEM CONFIGURATION

2.3 Applicable system

2 - 3
The QD70 is usable with the following system.
(1) Applicable module and the number of modules that can be installed
The following are the CPU module and network module (for remote I/O stations)
in which the QD70 can be installed and the number of modules that can be
installed.
Applicable module
CPU module
Network module
1 See User's Manual (Function Explanation, Program Fundamentals) for the CPU module to use.
2 See Q Corresponding MELSECNET/H Network System Reference Manual (Remote I/O
network).
(2) Base unit in which the QD70 can be installed
The QD70 can be installed in any I/O slot ( 3) of the base unit. However, a
power shortage may occur depending on the combination with other installed
modules and the number of modules used, so always take into consideration the
power supply capacity when installing modules.
3 Limited to the range of the number of I/O points in the CPU module and network module (for
remote I/O stations).
(3) Compatibility with a multiple PLC system
First read the QCPU (Q mode) User's Manual (Function Explanation, Program
Fundamentals) if the QD70 is used with a multiple PLC system.
Intelligent function module parameters
Perform PLC write of the intelligent function module parameters to the
control PLC of the QD70 only.
(4) Software packages supported
Correspondence between systems which use a QD70 and software packages
are as shown below.
The GX Developer is necessary when using a QD70.
If installed in the Q00J/Q00/Q01CPU
If installed in the Q02/Q02H/Q06H/Q12H/
Q25HCPU
If installed in the Q12PH/Q25PHCPU
If installed in a multiple PLC system
If installed in a MELSECNET/H remote I/O
station
Number of modules that
can be installed
Q00JCPU
Maximum 16
Q00CPU
Maximum 24
Q01CPU
Q02CPU
Q02HCPU
Q06HCPU
Maximum 64
Q12HCPU
Q25HCPU
Q12PHCPU
Maximum 64
Q25PHCPU
QJ72LP25-25
QJ72BR15
Maximum 64
QJ72LP25G
QJ71LP25GE
GX Developer
Version 7 or later
Version 4 or later
Version 7.10L or later
Version 6 or later
Version 6 or later
MELSEC-Q
Remarks
1
(
)
Can be installed in Q mode only
1
(
)
1
(
)
MELSECNET/H Remote I/O
2
station (
)
Software version
GX Configurator-PT
Version 1.10L or later
Version 1.13P or later
Version 1.10L or later
2 - 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd70p4Qd70Qd70p8Sw1d5c-qptu-eGx configurator-pt

Table of Contents