4 DATA USED FOR POSITIONING CONTROL

4.3 List of OPR data

Item
OPR. 1 OPR method
OPR. 2 OPR direction
OPR. 3 OP address
OPR. 4 OPR speed
OPR. 5 Creep speed
OPR. 6 ACC/DEC time at OPR
OPR. 7 DEC/STOP time at OPR 0 to 32767 (ms)
OPR. 8 Setting for the movement
amount after near-point
dog ON
OPR. 9 OPR dwell time
: When making setting in a sequence program, set 0 to 32767 in decimal as-is, and 32768 to 65535 in hexadecimal.
4 - 14
Setting value, setting
range
0: Near-point dog
method
1: Stopper 1
2: Stopper 2
3: Stopper 3
4: Count 1
5: Count 2
0: Forward direction
1: Reverse direction
-2147483648 to
2147483647 (pulse)
1 to 200000 (pulse/s)
1 to 200000 (pulse/s)
0 to 32767 (ms)
0 to 2147483647
(pulse)
0 to 65535 (ms)
OPR. 1 OPR method
Set the "OPR method" for carrying out machine OPR control.
0 : Near-point dog method....After decelerating at the near-point dog ON, stop at
1 : Stopper 1..........................After decelerating at the near-point dog ON, stop
2 : Stopper 2..........................After decelerating at the near-point dog ON, stop
3 : Stopper 3..........................After starting with the creep speed, stop with the
4 : Count 1.............................After decelerating at the near-point dog ON, move
5 : Count 2.............................After decelerating at the near-point dog ON, move
Note) Refer to "8.2.2 Machine OPR method" for details on the OPR methods.
Default value
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
0
20
120
0
21
121
22
122
0
23
123
24
124
1
25
125
26
126
1
27
127
1000
28
128
1000
29
129
30
130
0
31
131
0
32
132
the zero signal and complete the OPR control.
with the stopper, and complete the OPR control
after the OPR dwell time has passed.
with the stopper, and complete the OPR control with
the zero signal.
stopper, and complete the OPR control with the
zero signal.
the designated distance, and complete the OPR
control with the zero signal.
the designated distance, and complete the OPR
control.
MELSEC-Q
Setting value buffer memory address
220
320
420
520
221
321
421
521
222
322
422
522
223
323
423
523
224
324
424
524
225
325
425
525
226
326
426
526
227
327
427
527
228
328
428
528
229
329
429
529
230
330
430
530
231
331
431
531
232
332
432
532
620
720
621
721
622
722
623
723
624
724
625
725
626
726
627
727
628
728
629
729
630
730
631
731
632
732
4 - 14