1-Axis Linear Control - Mitsubishi Q Series User Manual

Positioning module, programmable logic controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

9 POSITIONING CONTROL

9.2.2 1-axis linear control

Setting item
Da. 1 Operation pattern
Da. 2 Control method
Da. 3 ACC/DEC time
Da. 4 DEC/STOP time
Da. 5 Command speed
Positioning address/
Da. 6
movement amount
Da. 7 Dwell time
Refer to "Section 4.5 List of positioning data" for the setting details.
9 - 11
In "1-axis linear control" (" Da. 2 Control method" = 1-axis linear control (ABS), 1-axis
linear control (INC), one motor is used to carry out position control in a set axis
direction.
[1] 1-axis linear control (ABS linear 1)
Operation chart
In absolute system 1-axis linear control, addresses established by a machine OPR
control are used. Position control is carried out from the current stop position (start
point address) to the address (end point address) set in " Da. 6 Positioning
address/movement amount".
Example
When the start point address (current stop position) is 1000, and the end point address (positioning address) is 8000,
position control is carried out in the positive direction for a movement amount of 7000 (8000-1000)
0
1000
Positioning control (movement amount 7000)
Positioning data setting example
The following table shows setting examples when "1-axis linear control (ABS)" is set
in positioning data No. 1 of axis 1.
Setting example
Positioning
Set "Positioning termination" assuming the next positioning data will not
termination
be executed.
1-axis linear
Set absolute system 1-axis linear control.
control (ABS)
1000ms
Set the acceleration/deceleration time for position control.
1000ms
Set the deceleration stop time for position control.
50000pulse/s Set the speed during movement to the positioning address.
8000pulse
Set the positioning address.
Set the time the machine dwells after the position control stop (pulse
500ms
output stop) to the output of the positioning complete signal.
Start point address
(current stop position)
MELSEC-Q
End point address
(positioning address)
8000
Setting details
9 - 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd70p4Qd70Qd70p8Sw1d5c-qptu-eGx configurator-pt

Table of Contents