4 DATA USED FOR POSITIONING CONTROL

4.4 List of JOG data

Item
JOG. 1 JOG speed
JOG. 2 JOG ACC time
JOG. 3 JOG DEC time
JOG. 4 JOG direction flag
4 - 20
Setting value, setting
range
1 to 200000 (pulse/s)
0 to 32767 (ms)
0 to 32767 (ms)
0: Forward run JOG
1: Reverse run JOG
JOG. 1 JOG speed
Set the speed for JOG operation. (This value is used for both forward run JOG
and reverse run JOG.)
Set the JOG speed in the following range.
( Pr. 5 Speed limit value) ≥ ( JOG. 1 JOG speed) ≥ ( Pr. 6 Bias speed at start)
If the "JOG speed" is more than the "speed limit value", it is limited to " Pr. 5
Speed limit value".
If the "JOG speed" is less than " Pr. 6 Bias speed at start", it is limited to "Pr. 6
Bias speed at start".
JOG. 2 JOG ACC time
Set the time taken to reach " JOG. 1 JOG speed" from " Pr. 6 Bias speed at
start" at a JOG operation start (JOG start signal ON). (This value is used for both
forward run JOG and reverse run JOG.)
JOG. 3 JOG DEC time
Set the time taken to make a stop after reaching " Pr. 6 Bias speed at start" from
" JOG. 1 JOG speed" at a JOG operation stop (JOG start signal OFF, error
occurrence). (This value is used for both forward run JOG and reverse run JOG.)
JOG. 4 JOG direction flag
Set the forward/reverse direction for JOG operation.
0: Forward run JOG
1: Reverse run JOG
Default value
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
40
140
0
41
141
1000
42
142
1000
43
143
0
44
144
MELSEC-Q
Setting value buffer memory address
240
340
440
540
241
341
441
541
242
342
442
542
243
343
443
543
244
344
444
544
640
740
641
741
642
742
643
743
644
744
4 - 20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd70p4Qd70Qd70p8Sw1d5c-qptu-eGx configurator-pt

Table of Contents