7. Installation

7.11 Column Cap and Bumper Supports

(Upper Drive Assembly)
With Safety Guard removed - Figure 7-13:
(Also See Special Set-Up Procedure -
Column Bumper Installation).
1) Install Column Cap (see Figure 7-12)
2) Install Bumper Supports
Important: Some bumper positions may
For more information on bumper settings,
contact your 3M service representative.
Figure 7-12
7.12 Box Size Capacity of Case Sealer
At its factory setting, case sealer handles a
variety of box sizes. If larger capacity is
needed, machine can be adjusted to
accommodate larger boxes (refer to
Specifi cations Section).
3M-Matic
7000r-7000r3 Pro
Page 26
(continued)
• Remove Column Cap and socket
head screw parts package from carton.
• Latching mechanism should be
installed on operator side column.
Raise and lock the upper drive
assembly in the raised position.
See Controls, Valves, Switch
Locations - Section 7.
• Turn off air supply and electric power.
• Remove the Column Bumper and fl at
head screw parts package from carton.
• Using fl at head screws provided, install
Column Bumper (recommended
position is shown in Figure 7-13).
• Install Safety Guard using socket
heads screws from parts package
allow upper and lower taping heads to
come into contact with each other.
This creates added stress to bumper and/
or can cause a malfunction of machine.
(Shown is
after Safety
Guard is
Removed)
Figure 7-13
7.13 Electrical Connections and Controls
The electrical and pneumatic "On/
Off " switch and the Push Button
Station "Start/Stop" are located on
the left side of the machine frame
(Figure 7-14). If desired, for operator
convenience, the "On/Off " and "Start/
Stop" switches can be relocated to
the right side of the machine frame.
A standard three conductor power
cord with plug is provided at the
back of the electrical control box for
(See Specifi cations) electrical service.
The receptacle providing this service
shall be properly grounded. Before
the power cord is plugged into outlet
make sure that all packaging materials
and tools are removed from the machine.
Do not plug electrical cord into outlet
until ready to run machine.
Use of an extension cord is not recom-
mended. However, if one is needed for
temporary use, it must have a wire size
of 1.5mm diameter [AWG16], have a
maximum length of 30.5m [100 ft] and
must be properly grounded.
Note - Machines outside the U.S. may
be equipped with 220/240 Volt, 50Hz
systems, or other electrical require-
ments compatible with local practice.

7.14 Initial Start-Up of Case Sealer

After completing the "Installation and
Set-Up" procedure, continue through
"Operation" for tape loading and
start-up to be sure case sealer is
properly adjusted to run boxes.