11. Set-Up and Adjustments
11.5 Special Set-Up Procedure for
Outer Column Re-Positioning
(continued)
Moving the outer columns will
increase or decrease the box height
handled by the 8000a-I / 8000a3-I
case sealer.
Maximum Height:
An additional adjustment can be
made to reach Maximum Height.
This additional height adjustment
can be made by moving the Upper
Assembly Crossbar up to top holes -
(Figure 11-8).

11.6 Run Boxes to Check Adjustment

Turn electrical switch "On" (I) to
start drive belts.
Move box forward under upper
taping head until it is taken away by
drive belts. If box is hard to move
under head or is crushed, raise head
slightly.
If the box movement is jerky or
stops under the upper head, move
the side drive belts in slightly to add
more pressure between the box and
drive belts.
Important – If drive belts are allowed
3M-Matic
8000a-I / 8000a3-I - Type 11700
Page 26
44-0009-2161-7 / ECO# 0078483
(continued)
to slip on box, excessive belt wear
will occur.
Figure 11-8