7-INSTALLATION AND Setup (continued)
WARNING
• To reduce the risk associated with
impact hazards:
− Always use appropriate supporting
means when working under the upper
drive assembly
• To reduce the risk associated with
mechanical and electrical hazards:
− Allow only properly trained and
qualifi ed personnel to operate and/or
service this equipment
7.11 Bumper Supports (Upper Drive Assembly)
With the Safety Guard removed (Figure 7-12):
Also See Special Setup Procedure -
Column Bumper Installation
Raise and lock the upper drive assembly
in the raised position.
See "Operation – Mechanical Latch."
Turn off air supply and electric power.
Remove the Column Bumper and set screw
parts package from the carton.
Using set screws provided, install
Column Bumper
(the recommended position is shown below).
Re-install Safety Guard.
* Important: - Some bumper positions may:
1) Allow upper and lower taping heads to come into
contact with each other.
2) Create added stress to the bumper.
3) Cause a malfunction of the machine.
These events can potentially cause damage to the machine.
For more information on bumper settings, contact
your 3M service representative.
700r3-NA
(Shown is
after Safety
Guard is
Removed)
Figure 7-12
7.12 Box Size Capacity of Case Sealer
At its factory setting, the case sealer handles box
sizes up to 620mm [24.5 inch] maximum height
(See Specifi cations Section). If larger capacity is
needed, the machine can be adjusted to
accom-modate boxes up to 725mm [28.5 inch] high.
Refer to "Special Setup Procedure –
Box and Machine Bed Height Range."
Note – Adjusting machine to accommodate 725mm
[28.5 inch] high boxes also increases minimum box
size to 170mm [6.8 inch].
7.13 Electrical Connections and Controls
The electrical control box and "On/Off" switch
are located on the lower left side of the machine
frame (See Figure 7-13). If desired, for operator
convenience, the "On/Off" switch can be relocated to
the right side of the machine frame. A standard three
conductor power cord with plug is provided at the
back of the electrical control box for 115 Volt, 60 Hz.,
3.8 Amp electrical service. The receptacle providing
this service shall be properly grounded. Before the
power cord is plugged into 115 Volt, 60 Hz outlet
make sure that all packaging materials and tools are
removed from the machine.
Do not plug electrical cord into outlet until ready
to run machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5mm diameter [AWG16],
have a maximum length of 30.5 m [100 ft], and
must be properly grounded.
WARNING
• To reduce the risk associated with
hazardous voltage:
− Position electrical cord away from foot
and/or vehicle traffi c
Note - Machines outside the U.S. may be equipped
with 220/240 Volt, 50 Hz systems, or
other electrical requirements compatible with
local practice.
7.14 Initial Start-Up of Case Sealer
After completing the "Installation and Setup"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes
24
2012 January