Box Height Range (Outer Column Repositioning) - 3M Matic 800at Instructions And Parts List

Adjustable case sealer with accuglide 2+ taping heads
Table of Contents

Advertisement

13-MAINTENANCE AND REPAIRS (continued)
Special Set-Up Procedure (continued)
WARNING
To reduce the risk associated with
mechanical and electrical hazards:
Turn electrical and air supply off and
disconnect before performing any
adjustments, maintenance, or servicing the
machine or taping heads
13.11.4 Box Height Range
(Outer Column – Re-Positioning)
Moving the outer columns to the upper set of
mounting holes increases the maximum box size
(height) handled by the case sealer from 620mm
[24-1/2 inches] to 725mm [28-1/2 inches].
Note – this also increases the minimum box height
from 120 mm [4-3/4 inches] to 210mm [8-1/4
inches].
800at-NA
To reduce the risk associated with
muscle strain:
Use the appropriate rigging and
material handling equipment when lifting or
repositioning this equipment
Use proper body mechanics when
removing or installing taping heads that are
moderately heavy or may be considered
awkward to lift
To Re-position the outer columns:
1. Remove special nut from the bottom of each
column lead screw. Figure 13-11A.
2. Remove plastic column cap from the top of each
outer column as shown in Figure 13-11B.
3. Crank upper assembly up, out of plastic nuts.
Lift upper assembly up and out of outer columns.
Be careful not to damage lead screws - Figure
13-11C.